MENU SCREEN
BIB EMPTY
XXREFILL
WTR START DELAY
WTR STOP DELAY
TEST LED’S ?
NO EXIT YES
TEST SWITCHES ?
UseSwitchToTest
TEST REFILL ?
EXIT YES
TEST HEATER ? EXIT YES
ENTER ASSET #
SERIAL #
LCA 0000000
VIEW FAULTS?
LATEST FAULT
NO FAULTS
FACTORY DEFAULTS
NO YES
ACTION | DESCRIPTION |
Use the (+) or | Used to set the Conductance Threshold for the |
adjust empty BIB threshold | Empty BIB warning. Default is 500 |
Use the (+) or | Used to set the Conductance Threshold for the |
adjust Refill threshold | Tank Refill Probe. |
Use the (+) or | Dispense Valve ON Delay. Eliminates weak mix |
adjust delay time | at the beginning of a dispense. |
Use the (+) or | Dispense Valve OFF Delay. Flushes the mix |
adjust delay time | chamber at the end of a dispense. |
Select (YES) or (NO) | LED diagnostics. Selecting YES will light all Front |
| Door LED’s. |
NONE | Switch Diagnostic: Activate switches separately to |
| test. Display will indicate which Switch has been |
| activated. NOTE: Door Interlock switch must be |
| held closed. |
Momentarily depress (YES) | Refill Valve Diagnostic: Press YES to momentarily |
| energize the Solenoid. CAUTION: Inlet Valve will |
| open and water will flow, if connected and turned |
| ON. |
Momentarily depress (YES) | Tank Heater Diagnostic: Press YES to momentarily |
| energize the Tank Heater Circuit. |
| CAUTION: AC power will be applied to the Tank |
| Heater Circuit. |
Use the (+) or | Allows the user the option of entering an Asset |
adjust the ASSET NUMBER | Number. Default is 000000 |
NONE | Displays the manufacture’s Serial Number (should |
| be identical to the Serial Number on the machine |
| Data Plate) |
Select (+) to view Fault | This unit stores the last 3 Fault Conditions in |
Conditions | memory for diagnostic purposes. |
Use (+) or | Displays up to 3 FAULT Conditions or NO FAULTS, |
the Faults | if nothing has failed since the last “Reset Factory |
| Defaults”. |
Select (YES) or (NO) | CAUTION: Selecting YES will RESET all |
| Programming Functions to the Factory Default |
| settings. NOTE: On LCC Models the Chiller will |
| have to be reset to the ON condition, (see Chilled |
| Unit programming function). |