MENU SCREEN

MENU SCREEN

BIB EMPTY -> 500

(-) EXIT (+)

XXREFILL -> 155 (-) EXIT (+)

WTR START DELAY

(-) .15SEC (+)

WTR STOP DELAY

(-) .15SEC (+)

TEST LED’S ?

NO EXIT YES

TEST SWITCHES ?

UseSwitchToTest

TEST REFILL ?

EXIT YES

TEST HEATER ? EXIT YES

ENTER ASSET #

(-) 000000 (+)

SERIAL #

LCA 0000000

VIEW FAULTS? (-) EXIT (+)

LATEST FAULT

NO FAULTS

FACTORY DEFAULTS

NO YES

ACTION

DESCRIPTION

Use the (+) or (-) buttons to

Used to set the Conductance Threshold for the

adjust empty BIB threshold

Empty BIB warning. Default is 500

Use the (+) or (-) buttons to

Used to set the Conductance Threshold for the

adjust Refill threshold

Tank Refill Probe.

Use the (+) or (-) buttons to

Dispense Valve ON Delay. Eliminates weak mix

adjust delay time

at the beginning of a dispense.

Use the (+) or (-) buttons to

Dispense Valve OFF Delay. Flushes the mix

adjust delay time

chamber at the end of a dispense.

Select (YES) or (NO)

LED diagnostics. Selecting YES will light all Front

 

Door LED’s.

NONE

Switch Diagnostic: Activate switches separately to

 

test. Display will indicate which Switch has been

 

activated. NOTE: Door Interlock switch must be

 

held closed.

Momentarily depress (YES)

Refill Valve Diagnostic: Press YES to momentarily

 

energize the Solenoid. CAUTION: Inlet Valve will

 

open and water will flow, if connected and turned

 

ON.

Momentarily depress (YES)

Tank Heater Diagnostic: Press YES to momentarily

 

energize the Tank Heater Circuit.

 

CAUTION: AC power will be applied to the Tank

 

Heater Circuit.

Use the (+) or (-) buttons to

Allows the user the option of entering an Asset

adjust the ASSET NUMBER

Number. Default is 000000

NONE

Displays the manufacture’s Serial Number (should

 

be identical to the Serial Number on the machine

 

Data Plate)

Select (+) to view Fault

This unit stores the last 3 Fault Conditions in

Conditions

memory for diagnostic purposes.

Use (+) or (-) to scroll through

Displays up to 3 FAULT Conditions or NO FAULTS,

the Faults

if nothing has failed since the last “Reset Factory

 

Defaults”.

Select (YES) or (NO)

CAUTION: Selecting YES will RESET all

 

Programming Functions to the Factory Default

 

settings. NOTE: On LCC Models the Chiller will

 

have to be reset to the ON condition, (see Chilled

 

Unit programming function).

19