Master Arm Delay

Default: P

Selection: Blank, E, or P

PPasscode: Required for all users with Master Arm Delay enabled for their authority level.

EEnable: A user does not need a passcode to use [COMMAND][1].

Blank

Disable Master Arm Delay cannot be

 

accessed in the function menu or

 

initiated with a command even if this

 

function is enabled for the user’s

 

authority level.

#2 Master Arm Delay [COMMAND][1]

Use this arming function to master arm disarmed areas. If enabled, the following arming choices are available to the user with this authority.

Mstr Arm Inst

Default: Blank

Selection: Blank, E, or P

#3 Master Arm Instant [COMMAND][1][1]

Use this arming function to master arm instant areas that are disarmed. If enabled, the following arming choices are available to the user with this authority. Entry and exit delays are not provided with this arming function. This causes a Perimeter and Interior Delay point to act as an Instant point.

Perim Instant

Default: P

Selection: Blank, E, or P

#4 Perimeter Instant Arm [COMMAND][2]

Instant arms all perimeter points with a P## Point Response that initiates an instant alarm (see P## Pt Response in Section 4.1.1 Point Responses) in the area where the command center is assigned. Entry and exit delays are not provided with this arming function. This function causes a Perimeter Delay point to act as a Perimeter Instant point.

Perim Delay

Default: P

Selection: Blank, E, or P

#5 Perimeter Delay Arm [COMMAND][3]

Delay arms all Perimeter points in the area where the command center is assigned. Entry and exit delays are provided with this Arming function. This function does not cause a Perimeter Instant point to act as a Delay point.

Watch Mode

Default: E

Selection: Blank, E, or P

#6 Watch Mode [COMMAND][6]

This function lets you know when a perimeter and Interior point programmed as P## Watch Point is faulted when the point is disarmed. Interior points do not emit a Watch Tone if the area is perimeter armed. This function provides command center audible/visual and optional relay activation (see A # Watch Mode in Section 2.13.1 Area Relays).

Perim Partial

Default: P

Selection: Blank, E, or P

#7 Perimeter Partial Arm [COMMAND][8]

Arms normal Perimeter points only while other faulted Perimeter points programmed as P## Bypassable are ignored. Entry and exit delays are provided with this Arming function.

Perim Partial ignores the A# FA Bypass Max entry in Section 2.9 Area Parameters.

Local Only Reporting: No Closing Report is sent to the central station, but a Perimeter Delay Closing Event is generated in the event log.