D9412G/D7412G Program Entry Guide 2.0 9000MAIN

EN 44

A# Area O/C

Default:

Yes

Selection:

Yes or No

 

 

 

Yes

Include the Area # and generate Opening and

 

Closing Reports for this area when it is armed.

 

 

No

Do not include the Area # or generate

 

Opening and Closing Reports for this area.

 

 

 

Determines if the area number and the account number are reported upon arming and disarming. As long as Account O/C is No, the account number reports when arming this area individually. If Account O/C is Yes, all areas with the same account number must also be armed.

An Area Opening Report is generated when each area is opened (disarmed). An Area Closing Report is generated when each individual area is closed (armed).

Do not program this item as Yes if the control panel reports to an automation system that cannot interpret multiple Area Opening/Closing Reports.

A# Disable O/C in Window

Default: Yes

Selection: Yes or No

Yes Do not send Opening and Closing Reports to the central station if they occur inside an active window.

If an Opening or Closing Report occurs outside a window, send it with an early or late modifier. See Section 5.1.1 Opening and Closing.

The active window must be a Closing Window for Closing Reports. It must be an Opening Window for Opening Reports.

No Send Opening and Closing Reports to the central station even when they occur inside a programmed window. If an opening or closing occurs outside of the appropriate window, it reports but does NOT have an early or late modifier.

If you want to monitor all opening and closing activity, but you also want to use features provided by Opening and Closing Windows, program this item No, and program appropriate O/C Windows.

Determines if opening and closing activity is reported when it occurs inside an Opening or Closing Window as programmed in O/C Windows.

Reports are always logged and printed on a local printer, if installed.

A# Auto Close

Default:

No

Selection:

Yes or No

 

 

 

Yes

The area automatically master arms at the end

 

of the Close Window.

 

When the area is armed automatically, a

 

Closing Report is sent if Area and/or Account

 

Reports are programmed to do so.

 

 

No

Do not automatically arm the area at the end

 

of the Close Window.

 

 

 

With this program item, the control panel can automatically master arm the area at the end of the Closing Window regardless of the previous armed state.

Regardless of A# Force Arm Max or P## Bypassable, an unconditional force arm occurs resulting in faulted points being left out of the system until they return to normal.

A# Fail to Open

Default: No

Selection: Yes or No

Yes

Fail to Open Report occurs for this area if the

 

area was not disarmed when the Opening

 

Window stop time occurred.

 

 

No

Fail to Open Report is not sent for this area.

 

 

Use to determine if a Fail to Open Report is sent for this area. This can determine if a user failed to disarm the area prior to the Opening Window expiring. Normal Opening and Closing Reports do not need to be programmed to use this feature.