A# Fail to Close

Default:

 

No

 

Selection:

 

Yes or No

 

 

 

Yes

Fail to Close Report occurs for this area if the

 

area was not armed when the Closing

 

Window stop time occurred.

 

Note:

 

 

An exit delay time must be programmed in Exit

 

 

Dly Time.

 

 

No

Fail to Close Report is not sent for this area.

 

Note:

 

 

If Auto Close is programmed Yes, a Fail to

 

 

Close Report is sent because it occurs when the

 

 

Closing Window stop time occurred.

 

 

If Disable O/C in Window is Yes, the Fail

 

 

to Close Report is followed by Closing Late or

 

 

F(orce) Close Late.

 

 

 

 

Determines if a Fail to Close Report is sent for this area. Use to determine if a user failed to arm the area before the Closing Window expires. Normal Opening and Closing Reports do not need to be programmed to use this feature.

A# Restrictd O/C

Default: No

Selection: Yes or No

Yes Restrict Opening and Closing Reports for this area. A# Area O/C must be programmed Yes to generate Restricted Opening and Closing Reports.

Note:

If a passcode is not required for arming or disarming and this item is Yes, the area only sends Restricted Opening and Closing Reports. In this case, Restricted Reports are sent without User ID.

Opening/Closing Window does not affect this report. Windows do not prevent Restricted Opening and Closing Reports from being sent. Early or late designations are NOT added to Opening/Closing Reports when they are sent according to the rules for Restricted Opening/Closing Reports.

No Do not Restrict Opening and Closing Reports for this area.

Regardless of programming in Authority Levels L## Restricted O/C, reports are not restricted in this area when this item is programmed No.

Note:

Was Force Armed and Forced Close Events can still be sent to the central station if enabled in Routing when force arming the system.

This item determines if this area can restrict Opening and Closing Report activity.

A Restricted Opening Report refers to the control panel sending an Area Opening Report only when the area is disarmed after a non-fire alarm.

A Restricted Closing Report refers to the control panel sending an Area Closing Report only when the area was master armed with Controlled points that were faulted during the arming sequence. The sequence of reports generated by a restricted closing is: Was Force Armed, Forced Point, Forced Close, and Closing Report.

Bosch Security Systems 1/04 47775E

Page 45
Image 45
Bosch Appliances D7412G, D9412G manual # Fail to Close, # Restrictd O/C

D7412G, D9412G specifications

Bosch has established itself as a leader in the appliance industry, known for its commitment to innovation, performance, and design. Among its impressive lineup, the Bosch D9412G and D7412G stand out as two highly sought-after models that combine advanced technologies with user-friendly features.

The Bosch D9412G is designed for those who demand top-of-the-line efficiency and functionality in their kitchen appliances. One of its most notable features is the powerful dual-fan system that ensures even and efficient cooking. This model is equipped with a robust stainless steel build and sleek finish, offering both durability and style.

The D9412G also boasts Bosch's innovative AutoCook technology, which automatically adjusts cooking times and temperatures based on the selected dish. This feature not only simplifies meal preparation but also ensures consistent results every time. Additionally, the model includes a built-in sensor that monitors food moisture levels, making it easier to achieve perfectly cooked meals without constant supervision.

In contrast, the Bosch D7412G caters to users seeking a balance of practicality and modern design. It maintains many of the advanced features of the D9412G while being more compact, making it ideal for smaller kitchens. The D7412G also utilizes the dual-fan system, ensuring that cooking is quick and even, with reduced energy consumption.

Both models are equipped with Bosch’s EcoSilent motor, which provides powerful performance while maintaining whisper-quiet operation. This is particularly beneficial for open-concept living spaces where noise levels matter. Additionally, both appliances come with a variety of cooking modes, including convection baking, broiling, and roasting, offering users versatility in their culinary endeavors.

The Bosch D9412G and D7412G also focus on user experience, with intuitive controls and easy-to-read displays that allow for effortless navigation. Their self-cleaning features save time and effort, ensuring that maintaining a clean appliance is straightforward.

In summary, Bosch's D9412G and D7412G models epitomize modern appliances that seamlessly blend technology and design with high-performance cooking capabilities. Whether you choose the high-capacity D9412G or the space-saving D7412G, you can expect exceptional results in your culinary endeavors, backed by Bosch's reliable engineering and quality.