D9412G/D7412G Program Entry Guide 2.0 9000MAIN

EN 48

CC# A1[through A8] in Scope

Default:

See preceding important note

Selection:

Yes or No

 

 

Yes

Include this area in the scope of this

 

command center.

 

 

No

Do not include this area in the scope of

 

this command center.

 

 

Determines whether any of the eight areas (Area 1 to Area 8) and Doors (Door 1 to Door 8) are included in the scope of this command center for viewing status, arming or disarming, and controlling doors from the command center.

CC# Entr Key Rly

Default:

Blank

Selection:

1 to 128, A, B, C, and Blank

 

 

Blank

The [ENTER] key is not used to cycle

 

a relay.

 

 

1 to 128,

Assign the relay number that activates

A, B, C

when [ENTER] is pressed at this

 

command center after the user enters a

 

valid passcode.

 

 

Enter Key Relay: Program the relay number that momentarily activates for 10 seconds when a user enters a valid passcode and presses the [ENTER] key on the command center. Two events are generated when this function is used: RELAY ###

SET with User ID, and RELAY ### RESET without User ID.

When programmed to activate a relay, the [ENTER] key cannot be used for any other function.

Relays used for this function must not be shared with any other point, sensor reset, control panel, or bell functions. This can cause erroneous relay operation.

1. Entering a valid code and pressing [ENTER] silences a bell if one is ringing.

2.Use this function for a low-level access control strike on a door. This does not shunt a point.

3.This action is logged as two events, Relay Set and Relay Reset.

CC# Entr Cycl Dr

Default: No

Selection: Yes or No

Yes

The [ENTER] key is used to cycle the

 

door programmed for CC Assign

 

Door.

 

 

No

The [ENTER] key is not used to cycle

 

the door.

 

 

Enter Key Cycle Door: Program this prompt as Yes to initiate the door cycle sequence (this includes shunting the point assigned to the door) for the door number programmed in CC Assign Door when a user enters a valid passcode and presses [ENTER]. ACCESS GRANTED prints on the local printer and at the central station receiver, if programmed.

The service passcode cannot be used for the CC# Entr Cycl Dr application.

When programmed to activate a relay, the [ENTER] key cannot be used for any other function.

Relays used for this function must not be shared with any other point, sensor reset, control panel or bell functions. This can cause erroneous relay operation.

 

1. The door does not cycle if Entr Key

0101

Rly is programmed.

2.9210 NOT READY appears at this command center when you press [ENTER] if the D9210B is not programmed with a D# Entry Area (in the RADAXS handler) or if CC Assign Door does not have a door number assigned.