D9412G/D7412G Program Entry Guide 6.0 RADXAUX1
EN 118
When configuring this item to allow for local programming, the D9133 needs Jumper 8 shorted, power must be cycled after changing the address, and a standard serial modem cable is required.
Call Back Enabled
Default: | No |
Selection: | Yes or No |
Yes | When the control panel hears the |
| proper RAM password (see RAM |
| Passcode in Section 2.7 RAM |
| Parameters), it ends the SDI RAM |
| session and then attempts to reconnect |
| to RAM using the RAM IP Address if |
| Enable Ext Modem is set to No. If |
| Enable Ext Modem is set to Yes, the |
| control panel attempts to |
| communication with RAM using the |
| RAM Dial String. This ensures that the |
| control panel only communicates with |
| valid RAM units. |
|
|
No | The SDI RAM session is initiated |
| immediately; no call back is required. |
| The control panel can engage in SDI |
| RAM sessions regardless of originating |
| location. |
|
|
Using this function allows the control panel, after verifying the RAM passcode, to provide an additional level of security. Before allowing any upload or download, it ends the SDI RAM session and then reconnects with RAM using one of the following:
•The RAM IP Address (Enable Ext Modem must be set to No)
•The RAM Dial String (Enable Ext Modem must be set to Yes)
In firmware version 6.30, do not enable RAM Call Back when using an external modem.
RAM IP Address 1
Default: | 0 | |
Selection: | 0 to 255 | |
0 to 255 | Enter the first three digits of the IP | |
| address. If the field is one or two digits | |
| in length, leading zeros are not | |
| required. | |
|
|
This prompt and the next three prompts determine the IP address for RPS.
An IP address consists of four fields. Each field has a range of 0 to 255. For example, an IP address is expressed as 110.227.64.190. The D5200 programmer splits the IP Address into four programmable fields. Be sure you contact your network administrator to find out the IP address to which the RPS computer is connected.
Figure 6: RAM IP Address Prompts
110.227.64.190
RAM IP Address 1
RAM IP Address 2
RAM IP Address 3
RAM IP Address 4
Set this item to 0 if Enable Ext Modem is set to Yes.
RAM IP Address 2
Default: 0
Selection: 0 to 255
See RAM IP Address 1.
RAM IP Address 3
Default: 0
Selection: 0 to 255
See RAM IP Address 1.
RAM IP Address 4
Default: 0
Selection: 0 to 255
See RAM IP Address 1.
6.4.2Using an External Modem
Through the use of a standard,
Bosch Security Systems 1/04 47775E