CF### Key Strokes
Default: | See Program Record Sheet | ||
Selection: | Up to 32 characters: 0 to 9, A, B, C, | ||
| D, and E |
| |
|
|
| |
Selection | Key | Faceplate Label | |
|
|
| |
0 to 9 | 0 to 9 |
| |
|
|
| |
A | [COMMAND] |
| |
|
|
| |
B | [PREV] (previous) | ↑ | |
|
|
| |
C | [ESC] (escape) | MENU | |
|
|
| |
D | [NEXT] | ↓ | |
|
|
| |
E | [ENT] (enter) | YES | |
|
|
|
The keystrokes simulate any sequence of keystrokes the user can perform at a command center. You can program up to 32 keystrokes for each Custom Function.
| D5200 Data Entry: Use the D5200 [↓ ] |
0101 | key to move the cursor to the first data |
| entry line. When you want to enter more |
| than sixteen keystrokes, the first line of the |
| data entry line must be filled before you |
| move on to the second line. If you make |
| entries on the second line, and the first line |
| has less than sixteen characters, the |
| second line clears when you press |
| [ENTER]. |
| The scope of the command center where |
0101 | the Function List is accessed can affect |
| the way the Custom Function operates. |
Programming Custom Function Keystrokes
•First, find the command you want to execute in the User Interface section of the Program Record Sheet.
•Single digit commands must be programmed with 9 as the second digit.
Table 24: CF### Custom Function Keystrokes
| Command | Keystroke |
| |
| 1 | (Master arm area) | A19 |
|
| 2 | (Perimeter instant arm) | A29 |
|
| 3 | (Perimeter delay arm) | A39 |
|
| 6 | (Watch Mode) | A69 |
|
| 7 | (Special alert) | A79 |
|
| 8 | (Perimeter partial arm) | A89 |
|
| 9 | ( Special alert) | A99 |
|
| 0 | (Bypass a point) | A09 |
|
|
|
|
|
|
|
|
|
|
|
•128 to 143 Enable Custom Function 128 through 143, (Menu Function only): This function determines if a passcode is required when attempting to access a Custom Function from the menu list. ENTER PASSCODE (or
Enter Passcode + Enter Key on the D1260) displays when this function is passcode protected.
| If a command within the Custom Function |
0101 | is passcode protected, the command |
| center displays ENTER PASSCODE and |
| waits for the user to enter a valid |
| passcode before proceeding with the rest |
| of the Custom Function. If a passcode is |
| not entered within 10 seconds, the |
| Custom Function times out and the display |
| returns to idle text. |
Skeds cannot execute Custom Functions that are passcode protected. D720 LED command center does not support Custom Functions that are passcode protected.
•Some functions cannot be entered directly because they are nested inside a
•For example: In the Change Display (COMMAND 49) function there are three sub- functions: Bright Display, Dim Display, and Date/Time Display.
-To turn up the display, enter: [A][4][9][E]
-To dim the display, enter: [A][4][9][D][E]
-To display time and date, enter: [A][4][9][B][E]