D9412G/D7412G Program Entry Guide 2.0 9000MAIN

EN 60

L## Perim Instant

Default:

See Program Record Sheet

 

 

Selection: Blank or E

#4 Perimeter Instant Arm [COMMAND][2]

Instant arm all Perimeter points, including Delayed points, only in the area where the command center is assigned.

L## Perim Delay

Default:

See Program Record Sheet

Selection: Blank or E

#5 Perimeter Delay Arm [COMMAND][3]

Delay arm all Perimeter Delay point responses only in the area where the command center is assigned.

L## Watch Mode

Default:

See Program Record Sheet

Selection: Blank or E

#6 Watch Mode [COMMAND][6]

Initiate the Watch Mode in the area to which this command center is assigned.

L## Perim Partial

Default:

See Program Record Sheet

Selection: Blank or E

#7 Perimeter Partial Arm [COMMAND][8]

Partially arms only the area where the command center is assigned.

This function ignores the A# FA Bypass

Max entry in Area Parameters.

Local Only Reporting: No Closing Report is sent to the central station, but a Perimeter Delay Closing Event is generated in the event log.

L## View Area Stat

Default:

See Program Record Sheet

Selection: Blank or E

#8 View Area Status (MENU FUNCTION only)

View the current arm/disarm and not ready to arm status of all areas within the scope of the command center in this area. The user needs arming/disarming authority.

L## View Memory

Default:

See Program Record Sheet

 

 

Selection: Blank or E

#9 View Event Memory [COMMAND][4][0]

View all memory events that occurred since the last time the system was armed for all areas within the scope of the command center in this area.

L## View Pt Status

Default:

See Program Record Sheet

 

 

Selection: Blank or E

#10 View Point Status (MENU FUNCTION only)

View the current status of all points in the area to which this command center is assigned.

L## Walk Test

Default:

See Program Record Sheet

 

 

Selection: Blank or E

#11 Walk Test [COMMAND][4][4]

Initiate a Walk Test for all Interior/Perimeter Controlled points in the area to which this command center is assigned.

The following features are provided with the Walk Test Mode:

During this test, the battery powers the control panel only. A Battery Test is initiated during the full duration of the test to ensure the battery capacity is capable of supporting the full load of the control panel while AC is failed.

-This test includes an initial 2-second Bell Test when starting the Walk Test.

-The test ends once all points are tested or until the test times out after 20 minutes of no activity.

Local alarm annunciation and event printing without reporting to the central station receiver.

D1255 command center displays a sequential count after each point is activated and restored as well as the text for the point.

The command center displays ALL PTS TESTED and an All Points Tested Event is reported to the central station receiver (if programmed) when the last point is tested.

If enabled in Routing, Walk Start and Walk End are reported at the central station receiver for the beginning and end of the test.