D9412G/D7412G Program Entry Guide 2.0 9000MAIN

EN 36

Figure 2: Account Number Entry

1

1

1

2

2

3

3

4

4

5

5

2

 

3

 

4

 

5

 

6

 

7

1 - RPS account number entry

2 - Corresponding D5200 account number digits

3 - Digits 1 and 2

4 - Digits 3 and 4

5 - Digits 5 and 6

6 - Digits 7 and 8

7 - Digits 9 and 10

Although the D5200 allows the character “A” to be entered into the account, do NOT use this character for the account number.

Make sure your central station receivers (D6500 MPU version 1.06 or D6600 CPU version 01.01.04) and your automation software are compatible with ten-digit account numbers before programming a ten-digit account number in a 9000 Series control panel.

A# FA Bypass Max

Default: 1

Selection: 1 to 99

Specify the maximum number of combined Controlled points that can be faulted or bypassed when arming this area.

See the prompts P## FA Retrnable and P## BA Retrnable in Section 4.1.1 Point Responses for returning a point to the system when the point returns to normal or when the area is disarmed.

Users can bypass more points than the number entered here during the disarmed state. It is only when the user attempts to Bypass Arm an area (or areas) that this restriction is enforced.

 

Points need Bypassable programmed Yes

0101

to be bypassed or force armed. Force

 

arming does not bypass 24-hour points.

A# Delay Res

Default:

No

Selection:

Yes or No

 

 

Yes

Point Restoral Report is not sent until

 

the bell time expires or user

 

acknowledges alarm condition.

 

 

No

Restoral Reports are sent when point

 

restores, regardless of bell time.

 

 

A# Exit Tone

Default: Yes

Selection: Yes or No

Sound an exit tone during exit delay at all command centers assigned to this area.

De-selecting individual command centers for exit tones: Exit tones for programming the CC Exit Tone as No can be turned off for individual command centers (based on their CC# 1 through 8).

A# Exit Dly Time

Default: 60

Selection: Blank (0) to 600 ( in 5 second increments)

Exit delay time for this area when Master Exit or Perimeter Exit arming.

Points programmed for instant alarms generate alarms immediately, even during exit delay. To prevent instant alarms on points, the user must cause a fault to leave the building, program P### Type in the Point Index as 3 (Interior Follower).