Conserver XLSeries Technical Manual 7610-002-10-23
Issued: 11-28-2007 Revised: N/A
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
CAM TIMER OPERATION
The Conserver XLSeries cam timer is a 1 minute, 30 second, 8-cam timer (cam 8 is a spare) that controls the operation of the
dishmachine. The following is a description of the set points for each cam and the function of each switch.
CAM 1: Cam 1 is a cut cam with a single notch and serves as the cycle/reset control.
FUNCTION: When the machine is in the operation mode the notch is the home position. The machine will remain idle until the
door is opened, then cam 1 moves to the start position and holds until the door is closed. The closing of the door will start the
next cycle. The cam will rotate a complete cycle, and return to the home position and hold.
CAM 2: Cam 2 is a cut cam and provides the wash cycle timing.
FUNCTION: The wash cam works off the normally open contacts of Cam 2. This requires the microswitch be held closed by
the cam. It will close and energize the wash pump 2 seconds after the cycle switch is activated. The pump will operate through
the wash cycle (40 seconds) then shut down for the dwell period (20 seconds). As the cam rotates it energizes the pump for
the rinse cycle (25 seconds). When cam 1 reaches it’s home position it will de-energize cam 2, shutting down the wash pump.
NOTE: The last 6 cams are adjustable. The following instructions will require that the timer position have the cams to
the front and the motor to the left.
CAM 3: Cam 3 is an adjustable cam and controls the drain valve.
FUNCTION: The drain solenoid works off the normally closed contacts of cam 3. When the cycle is initiated, the microswitch
will be held open until it is allowed to drop into the notch of the cam. This energizes the drain solenoid which drains the
machine. After a 12 second delay the cam reverses the microswitch, de-energizing the drain solenoid. This cam may require
adjusting due to varying water pressure. The drain solenoid must remain open long enough to remove whatever water the fill
valve solenoid allows in the machine. This could vary due to the water supply line pressure.
SETTINGS: The right side of cam 3 must be set to pick up the switch arm just before the wash/rinse cycle cam switch drops.
It will hold the drain solenoid open to drain all the water in the tank from the unit during the dwell period. Any adjustment made
to the drain should be made to the left side of cam 3. The cam must be moved back into the wash time until all of the water is
drained from the machine.
CAM 4: Cam 4 is an adjustable cam and controls the fill valve and therefore the amount of water used.
FUNCTION: The fill valve cam works off the normally closed contacts of cam 4. This requires the switch to be held open by the
cam and allowed to drop into the notch to operate the fill valve. This energizes the fill solenoid which opens to start filling the
machine with fresh water. After a 10 second delay, the cam reverses the microswitch, de-energizing the fill solenoid. The fill
cam may require adjustment due to varying water pressure. The fill solenoid must remain open a sufficient length of time to fill
the machine to the correct level.
SETTINGS: The right side of cam 4 must be set to allow the switch arm to drop 2 seconds before the drain solenoid is de-ener-
gized which flushes the detergent residue from the unit. It will hold the fill solenoid open until the cam switch arm is raised. At
that time the fill solenoid is de-energized, shutting off the incoming water. The tub will be filled to the correct level. Any adjust-
ment made to the timing of the fill solenoid should be made with the left side of cam 4. To increase the water level, open the
notch of the cam and for decreasing the level of the notch should be closed.
CAM 5: Cam 5 is an adjustable cam and controls the sanitizer pump.
FUNCTION: The sanitizer pump cam works off the normally closed contacts of cam 5. This requires the switch arm to be held
open by the cam and allowed to drop into the notch to operate the pump. The time that the sanitizer pump will remain ener-
gized must be determined in the field to suit the chemical used and water conditions.
SETTINGS: The left side of cam 5 must be set to allow the switch arm to drop in past the starting point of the fill cam and after
the drain solenoid has closed. The adjustment for sanitizer volume must be made with the right side of the cam. To increase
the volume the notch should be increased or to decrease the amount of sanitizer the notch should be closed slightly in incre-
ments until the correct level is reached.
20