Jackson AXL2-CMR, AXL2-CML technical manual INSTALLATION/OPERATION Instructions

Models: XL2-CML XL2-CMR AXL2-CMR AXL2-CML AXL2 AXL XL2

1 94
Download 94 pages 55.33 Kb
Page 28
Image 28

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

CAM TIMER OPERATION (CONTINUED)

CAM 6: Cam 6 is an adjustable can and controls the detergent pump.

FUNCTION: The detergent pump cam works off the normally closed contacts of cam 6. This requires the switch arm to be held open by the cam and allowed to drop into the notch to operate the pump. The time that the detergent pump will remain ener- gized must be determined in the field to suit the chemical used and water conditions.

SETTINGS: The left side of cam 6 must be set to drop in past the starting point of the wash pump cam. The adjustment for detergent volume must be made with the right side of the cam. To increase the volume, the notch should be increased or to decrease the amount of detergent the notch should be closed slightly in increments until the correct level is reached.

CAM 7: Cam 7 is an adjustable cam and controls the rinse aid pump.

FUNCTION: The rinse aid pump cam works off the normally closed contacts of cam 7. This requires the switch arm to be held open by the cam and allowed to drop into the notch to operate the pump. The time that the rinse aid pump will remain ener- gized must be determined in the field to suit the chemical used and water conditions.

SETTINGS: The left side of cam 7 must be set to drop in past the starting point of the fill cam and after the drain solenoid has closed. The adjustment for rinse aid volume must be made with the right side of the cam. To increase the volume the notch should be increased or to decrease the amount of detergent the notch should be closed slightly in increments until the correct level is reached.

Conserver XL Series Technical Manual 7610-002-10-23

Issued: 11-28-2007 Revised: N/A

21

Page 28
Image 28
Jackson AXL2-CMR, AXL2-CML technical manual INSTALLATION/OPERATION Instructions