Conserver XLSeries Technical Manual 7610-002-10-23
Issued: 11-28-2007 Revised: N/A
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
ELECTRICAL INSTRUCTIONS
16
ELECTRICAL POWER CONNECTION: Electrical and grounding connections must comply with the applicable portions of the
National Electrical Code ANSI/NFPA70 (latest edition) and/or other electrical codes.
Disconnect electrical power supply and place a tag at the disconnect switch to indicate that you are working on the circuit.
The dishmachine data plate is located on the right side and to the front of the machine. Refer to the data plate for machine
operating requirements, machine voltage, total amperage load and serial number.
To install the incoming power lines, open the control box. This will require taking a phillips head screwdriver and removing the
one (1) screw on the front cover of the control box. Install 3/4” conduit into the pre-punched holes in the back of the control box.
Route power wires and connect to power block and grounding lug. Install the service wires (L1 & N) to the appropriate termi-
nals as they are marked on the terminal block. Install the grounding wire into the lug provided.
It is recommended that “DE-OX” or another similar anti-oxidation agent be used on all power connections.
VOLTAGE CHECK:Ensure that the power switch is in the OFF position and apply power to the dishmachine. Check the incom-
ing power at the terminal block and ensure it corresponds to the voltage listed on the data plate. If not, contact a qualified ser-
vice agency to examine the problem. Do not run the dishmachine if the voltage is too high or too low. Shut off the service break-
er and mark it as being for the dishmachine. Advise all proper personnel of any problems and of the location of the service
breaker. Replace the control box cover and tighten down the screws.
This equipment is not recommend for use with deionized water or other aggressive fluids. Use of deionized
water or other aggressive fluids will result in corrosion and failure of materials and components. Use of
deionized water or other aggressive fluids will void the manufacturer's warranty.