ON P1 13 : 17
OFF
ADVANCE
AUTO MAN ON OFF
Fig. 5
Digital Timer Operation (CVP1T model only)
IMPORTANT: Remember to observe all safety warnings when operating the heater on auto setting, either attended or unattended.
The timer allows you to select ‘AUTO’, ‘MAN ON’ or ’MAN OFF’ by pressing the ‘MODE’ button until the required MODE appears at the bottom of the timer display.
‘AUTO’ MODE allows the heater to switch ON and OFF according to a set 24 Hour program period (see ‘Setting Programs’ section below). ‘MAN ON’ MODE allows power to the heater uninterrupted by the program settings.
‘MAN OFF’ MODE switches off all heater operation completely. Key Lock:
If ‘ENTER’ and ‘MODE’ are pressed within 1 second, the keys will be locked. The user will know the keys are locked as the lock symbol ‘’ will be displayed on the top left hand corner of the screen. To unlock the keypad, press ‘ENTER’ and then ‘MODE’ within 1 second.
Initial Operation
For initial use, plug the heater into a regular household power point and turn the power on. The timer is now ready to be set up for use.
Setting Current Time
1.Press the ‘PROGRAM’ button ONCE. The clock symbol appears on the top left hand side of the screen. The user can now set the clock.
2.The hour digit will flash. To adjust the hour use the
3.Once ‘ENTER’ has been pressed the minutes will flash. To adjust the minutes use the
4.The timer now returns to the default display.
5.To reset incorrect time, repeat previous steps.
Once the correct time is set, a total of four ON/OFF time programs can be set for operation. There are two program options.
Setting Programmes
Press the ‘PROGRAM’ key twice to set the programs. You are now setting the programs starting with P1 ‘ON’.
SETTING P1 ON TIME:
1.To set the hour use the
2.To set the minutes use the
Note: The minutes can only be set in 10 minute blocks in programme ‘MODE’.
SETTING P1 OFF TIME:
3.To set the hour use the
4.To set the minutes use the
Repeat steps 1 to 4 to programme P2, P3 & P4. After programming P4 ‘OFF’ you automatically exit to the default display.
At any time while programming the timer you can press the ‘PROGRAM’ button to exit to the default display.
The Advance Function
When in ‘AUTO’ MODE, if the ‘+’ button is pressed for longer than 2 seconds the programme will ADVANCE to the next setting programmed and will only revert back to the program when the subsequent programme time is reached. When the ‘ADVANCE’ function is running the ‘ADVANCE’ segment will be displayed on the LCD screen. If the
when the ‘ADVANCE’ programme is running the ‘ADVANCE’ feature will be automatically cancelled and the programme will run as normal.
Note - Timer Memory Back Up Batteries - Once the heater has been left plugged in with the socket switched on for at least 72 hours the timer’s memory back up batteries will be fully charged.
Once the timer batteries are fully charged, if there is a power cut or if the heater is disconnected from the mains for less than six months, then the timer will continue to keep time & the settings in the memory will remain intact.
If however the timer back up batteries have not been charged fully, or if the heater is deprived of power for longer than six months, then the time and the programme settings are likely to be lost and you may therefore need to reset the time and the programme before using the
AUTO MODE again.
Safety Overheat Protection
The heater is fitted with a thermal safety