D9412G/D7412G Program Entry Guide 7.0 RADXAXS
EN 131
7.0 RADXAXS
7.1Door Profile
This programming category is used to:
•Assign an area, that also activates the D9210B
•Assign a point to the door
•Program the door state to change when the arm state changes
•Allow for the Strike relay to activate upon a fire alarm
Door #
Default: 20 seconds
Selection: 1 seconds to 8 seconds
Enter the number of the door you are about to program.
The D9412G supports up to eight doors.
The D7412G supports two doors.
D# Entry Area #
Default: Blank
Selection: Blank, 1 to 8
1 to 8 | The area assigned to the door |
| controller to which the reader allows |
| access. |
|
|
Blank | Door controller does not function. |
|
|
Assign an area to the door controller. This entry allows the D9210B to be polled, activating communication to the control panel. This also is the area a user exits when initiating a REX.
All SDI devices, regardless of area assigned, report to Area 1, Account 1 by default upon SDI failure. If a D9210B becomes disconnected, an SDI Fail ## and a Missing Point ### Event is created.
| 9210 NOT READY appears at this |
0101 | command center when you press the |
| [ENTER] key if the D9210B is not |
| programmed with a D# Entry Area. |
D#CC#Scope
Default: Blank
Selection: Blank, 1 to 8
1 to 8 | Determines disarming rights. The |
| user’s access level in conjunction with |
| the CC # Scope determines which |
| areas are disarmed. |
Blank | Only the area assigned to the D# |
| Entry Area disarms this door. |
|
|
Enter the command center number (CC#) which determines the scope of the user ID’s disarming rights. Areas disarm on the basis of this command center’s scope and the authority level of the user.
D# Door Point
Default: Blank
Selection: Blank, 1 to 127, 129 to 247
1 to 127, | The point number assigned to this |
129 to 247 | door. Points 128 and 248 are reserved |
| by the control panel for internal use. |
|
|
Blank | There is no point number assigned to |
| this door. |
|
|
Enter the point number assigned to this door. This point cannot be used for any other point assignments.
Door points must be programmed as Perimeter points. If a
| When assigning Points 1 to 8 (control |
0101 | panel zones), the |
| resistors must be removed from the control |
| panel. In addition to this, do not enable any |
| POPIT points (or OctoPOPIT points) |
| sharing the same point number as the |
| Door point. Failure to do so results in extra |
| point trouble conditions upon reboot. |
Bosch Security Systems 1/04 47775E