![](/images/new-backgrounds/1012804/12804117x1.webp)
D9412G/D7412G Program Entry Guide 2.0 9000MAIN
EN 59
2.11.3 Authority Level Selections
Use Section 2.11.3 Authority Level Selections to determine which Authority Level can access command center functions that are Passcode Protected. You do not need to select Enable items in the Authority Level section if the command center function is disabled or enabled. There are two selections you can use for each individual function for the authority level you are programming.
Press the [SPACE] bar to scroll through the selections. Press [ENTER] when the correct selection appears in the display.
Table 26: Authority Level Selections
Authority Level | Description |
Blank | Disabled: This function is not |
| authorized for the user who is |
| assigned this authority level. |
E | Enabled: This function is authorized |
| for the user who is assigned this |
| authority level. |
|
|
Authority Level
Default: 1
Selection: 1 to 14
Enter the number of the authority level you want to program. Authority Level 15 (Service Passcode) cannot be edited.
L## Disarm
Default: | See Program Record Sheet |
Selection: Blank or E
#1 Disarm
Use the disarming function to disarm areas that are master armed or perimeter armed. If enabled, the following disarming choices are available to the user with this authority.
DISARM ALL: Disarms all areas within the CC# Scope of the command center being used by accessing the Function Menu and the authority level of the user performing the function.
DISARM AREA: Disarms only the displayed area.
| There are many options available for |
0101 | arming and disarming. This depends on A# |
| Area Type and CC# Scope. Read the |
| definitions of area type in Section 2.9 Area |
| Parameters and CC# Scope in Section |
2.10.1Cmd Cntr (Command Center) Assignment.
L## Master Arm Delay
Default: | See Program Record Sheet |
|
|
Selection: Blank or E
#2 Master Arm Delay [COMMAND][1]
Master arms areas based on the CC# Scope of the command center using an exit delay time.
When this item is accessed through the Function List, Master Arm All allows the user to arm all areas according to the authority level of the user and within the CC# Scope of the command center using an exit delay time.
Arm Area arms only the area displayed.
If COMMAND 1 is used, it arms only the area where the command center is assigned.
.L## Mstr Arm Inst
Default: | See Program Record Sheet |
|
|
Selection: Blank or E
#3 Master Arm Instant [COMMAND][1][1]
When this item is accessed through the Function List, Master Arm Inst allows the user to arm all areas according to the user’s authority level and within the CC# Scope of the command center being used without an exit delay time by accessing the Function Menu.
Arm Area arms only the area to which the command center is assigned.
If COMMAND 11 is used, it arms only the area where the command center is assigned.
Use COMMAND 11 carefully because all
Perimeter and Interior points become
Instant Armed.
Bosch Security Systems 1/04 47775E