Bunn VP17B service manual SERVICE cont LIMIT THERMOSTAT, BLU to BLU Lead from Control Thermostat

Models: VP17B VP17

1 19
Download 19 pages 4.79 Kb
Page 11
Image 11
SERVICE (cont.)

SERVICE (cont.)

LIMIT THERMOSTAT

P1161.40

FIG. 4 LIMIT THERMOSTAT

Location:

The limit thermostat is located inside the rear of the hood on the tank lid.

Test Procedures:

1.Disconnect the brewer from the power source.

2.Disconnect the blue and black wires from the limit thermostat.

3.With an ohmmeter, check for continuity across the limit thermostat terminals.

If continuity is present as described, the limit thermo- stat is operating properly.

If continuity is not present as described, replace the limit thermostat.

Removal and Replacement:

1.Remove all wires from limit thermostat terminals.

2.Carefully slide the limit thermostat out from under the retaining clip and remove limit thermostat.

3.Carefully slide the new limit thermostat into the retaining clip.

4.Refer to Fig. 5 when reconnecting the wires.

BLU to BLU Lead from

Control Thermostat

BLK to Terminal Block or Tank Heater Switch

P1800

FIG. 5 LIMIT THERMOSTAT TERMINALS

Page 11

10860

061501

 

 

Page 11
Image 11
Bunn VP17B service manual SERVICE cont LIMIT THERMOSTAT, BLU to BLU Lead from Control Thermostat