Co-linear Hearthmount Installation
The Jøtul GF 200 DV Lillehammer may be vented through a masonry fireplace using Simpson Dura- Vent Chimney Liner Conversion Kit 923GK. When installed in the manner described below, this system can improve the performance of the appliance in cold climate situations, as well as simplify the vent installation.
These guidelines must be followed:
Exhaust Gases
#923GK
Maximum Co- Top Kit Linear Height
- 35 FT
#991 |
High |
Wind Cap |
Intake Air
1. | Prior to the installation, the chimney flue must be |
| thoroughly cleaned and inspected by a qualified |
| chimney service person. |
2. | In a masonry chimney, a fireclay liner or listed |
| steel liner, must be present the entire length of |
| the chimney. |
3. | No appliance can be installed into a chimney flue |
| serving any other appliance of any kind. |
4. | The minimum length of the AIR INTAKE FLEX is 6 |
Minimum Co-
Linear Height
feet- measured off of the back of the appliance |
and IT MUST EXTEND PAST THE DAMPER AREA OF |
THE FIREPLACE. |
5. If the intake flex does not extend the full length |
of the chimney and connect to both the unit and |
the termination cap, A METAL BLOCK OFF PLATE |
MUST BE CONSTRUCTED AND INSTALLED ABOVE |
THE UNIT PRIOR TO THE END OF THE INTAKE FLEX |
AND MUST COMPLETELY SEAL THE CHIMNEY FLUE |
FROM THE ROOM. |
Consult with the local code authority having jurisdiction before proceeding with this type of installation.
Refer to the vent manufacturer’s instructions for specific installation requirements.
Air Intake flex pipe must extend a minimum of 6 ft. and through the damper area.
Chimney must be sealed off from the room by a steel plate at the damper area.
Dual 3” Flex Liners
WARNING: FAILURE TO POSITION THE PARTS AND STOVE IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED FOR USE WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. BE SURE TO MAINTAIN THE PROPER CLEARANCES TO COMBUSTIBLES AS DEFINED IN THIS MANUAL AND INM THE INSTRUCTIONS PROVIDED WITH EACH VENT
COMPONENT.
IMPORTANT NOTICE
THE USE OF AN EXISTING CHIMNEY AS AN AIR INTAKE IS NOT COVERED UNDER THE ANSI
TEST METHODS AND RESULTING ITS/WHI PRODUCT CERTIFICATION. THE CODE AUTHORITY HAVING JURISDICTION MUST BE CONSULTED PRIOR TO PRO- CEEDING WITH THIS INSTALLATION
#923GCL Co- Linear Appliance Adaptor
Figure 8. Co-Linear Vent System installed in a masonry fireplace.
21 1/2”
(546mm)
18”
(457 mm)
Figure 9. Co-Linear Adaptor dimensions with Plinth legs.
10