Jotul manual GF 200 DV Lillehammer Options, Input Rates, Natural Gas, Propane, Inlet Pressure

Models: GF 200 DV

1 28
Download 28 pages 892 b
Page 4
Image 4
Jøtul GF 200 DV Lillehammer Specifications

24”

610 mm

22 3/4” Input Rates 560 Natural Gas

mm

18 1/2”

16 1/2”

420

470 mm

mm

 

Rear Exit

Centerline

18”

460 mm

13”

330 mm

Figure 1. Dimensional Views - GF 200 DV Lillehammer

Jøtul GF 200 DV Lillehammer Specifications

Input Rates

Natural Gas

18,000 BTU/hr. maximum input

13,500 BTU/hr. minimum input

Propane

18,000 BTU/hr. maximum input

13,500 BTU/hr. minimum input

Inlet Pressure:

MIN

MAX

Natural Gas:

5.0 WC (1.24 kPa)

7.0 WC (1.74 kPa)

Propane:

11.0 WC (2.73 kPa)

13.5 WC (3.36 kPa)

Manifold Pressure:

MIN

MAX

Natural Gas:

2.2 WC (.54 kPa)

3.5 WC (.87 kPa)

Propane:

6.5 WC (1.61 kPa)

10.0 WC (2.49 kPa)

Efficiency: 82%

Steady State (A.F.U.E.): 73%

Piezo Ignitor / Standing Pilot

The Jøtul GF 200 DV Lillihammer is a Direct Vent wall furnace designed as a sealed combustion, air circulating gas appliance for residential applications. This appliance is approved for installation using 6 5/ 8" X 4" vent pipe from the following manufacturers:

Simpson Dura-Vent GS Security Vent, Ltd. Amerivent Inc.

The Jøtul Lillehammer gas stove is designed to burn NATURAL GAS or PROPANE only. It is shipped from the factory equipped to burn Natural Gas. If use with Propane is desired, the stove must first be converted for use with that gas. Use the LP Fuel Conversion Kit included with this stove See page 15.

GF 200 DV Lillehammer Options

Fuel Conversion Kit - NG

155349

Fuel Conversion Kit - LP

155350

• High Altitude Conversion Kit - NG

154371

• High Altitude Conversion Kit - LP

154373

Wall Thermostat

750003

Remote Control

129706

• Mobile Home Floor Bracket Kit

154342

4

Page 4
Image 4
Jotul manual GF 200 DV Lillehammer Options, Input Rates, Natural Gas, Propane, Inlet Pressure, Manifold Pressure