Gas Conversion Procedure

See Figure 29, page 25 for parts identification.

1.Turn off gas supply to the stove.

2.Remove the stove Top Plate (3).

3.Remove the Front Panel. Using a 10mm open- end wrench, loosen the two bolts holding the Front Panel (1) to the side panels (2). (Note: You do not have to remove these bolts.) Pull the Front Panel away from the stove and lift off of Bottom Plate.

4.Release the Glass Retainer Clips (12) on top of the firebox and carefully lift the Glass Panel up and out.

5.Remove the Logs (14) using care to avoid chip- ping or other damage.

6.Lift out the Air Deflector (17). Remove the Air Divider (16) by lifting right side and slowly rotating forward.

7.Remove Burner Tube (15): Using a ¼” nut driver, remove the two screws securing the Burner Tube to the stove bottom. Lift out the Burner Tube.

WHEN RE-INSTALLING THE BURNER TUBE, BE SURE THAT THE TUBE IS PULLED FORWARD IN THE MOUNTING HOLES. Secure with the two 1/ 4” screws.

8.Remove the Burner Orifice Holder Shield (18) around the orifice. Using a 1/4” nut driver remove the screw attaching the shield to the rear wall of the firebox. Slide the shield left and remove.

9.Change the Main Burner Orifice (38). Use a ½” open end wrench to remove the burner orifice and replace with the appropriate orifice supplied in the kit.

#48 for Natural Gas 3/64” for Propane

10.Adjust the Air Shutter on the Burner Tube (15) to allow for the proper mixing of air and gas. See fig. 16. The correct settings:

Open 1/8” for Natural Gas

Open 3/4” for Propane

11.Change the Pilot Orifice. From within the firebox, pull the Spring Clip back to release the Pilot Hood from the Pilot Base. Use the 4m mm hex key to remove the original Pilot Orifice from the base, (counterclockwise). See fig. 17.

Install the appropriate pilot orifice: #51 for Natural Gas

#30 for Propane.

Be certain the orifice is securely tightened. If the orifice is loose, gas flow will not be properly regulated.

Replace the Pilot Hood onto the base by re- engaging the spring clip around its collar.

12.Replace the variable Regulator. Using a Torx T-20 screwdriver, remove the three mounting screws

Open 1/8” for Natural Gas

 

 

 

 

Open 3/4” for Propane

Air Shutter

Burner Orifice

 

 

 

 

 

 

 

 

Burner Tube

Figure 16. Air Shutter adjustment and Burner Orifice.

Pilot Hood

Pilot Orifice

Spring

Clip

Pilot Base

Figure 17. Pilot assembly and orifice.

16

Page 16
Image 16
Jotul GF 200 DV manual Gas Conversion Procedure, Air Shutter adjustment and Burner Orifice