3.Burner Adjustment: The Lillehammer is equipped with a variable gas control valve. that provides easy adjustment of the flame height appearance and heat output. To adjust the flame between the HI and LOW setting, rotate the HI/ LOW knob, located in the center of the valve face.

Flame height will adjust approximately 1.0” to 1.5” between the LOW and HIGH settings. See Figure 26.

NO SMOKE OR SOOT SHOULD BE PRESENT. CHECK LOG PLACEMENT IF ANY SOOT OR SMOKE IS DETECTED. IF SOOT OR SMOKE PERSIST, THE AIR SHUTTER MAY NEED TO BE ADJUSTED.

See Air Shutter/Flame Appearance section of this manual for proper air shutter settings and adjustments. Note: the more offsets on the vent system, the greater the need for an air shutter adjustment.

WARNING: AIR SHUTTER ADJUST- MENTS SHOULD ONLY BE PERFORMED BY A QUALIFIED PROFESSIONAL SER- VICE TECHNICIAN.

3” - 4” 3” - 4”

1” - 2”

Figure 26. Correct flame picture.

The illustration above depicts the flame appear- ance on the “high” setting after burning approxi- mately 15 to 20 minutes.

CAUTION: DO NOT ATTEMPT TO ALTER THE FLAME APPEARANCE BY POSITION- ING THE GAS VALVE IN ANY OTHER POSI- TION OTHER THAN THE FULL “ON” POSI- TION.

Operation of Appliance

1.Always follow the Safety Guidelines and Lighting Instructions found on page 27 (inside back cover). These instructions are also found on the metal Rating Plate attached to the stove.

2.The Lillehammer is equipped with an On/Off/T- stat rocker switch or can be controlled using an optional wall mounted thermostat.

3.When lit for the first time, the Lillehammer will emit an odor for several hours. This odor is the burn-off by-products of internal paints and lubricants used in the manufacturing process.

4.Condensation may occur on the glass upon each lighting of the appliance. This “fog” will disappear as the appliance heats up.

5.Keep the controls and the area under the appli- ance free of debris, vacuum this area frequently. Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids.

If and when a vacuum is used for any service on the stove, ALWAYS be sure the stove is cold and that there are NO hot embers or sparks.

6.Remember, this appliance has a continuous burning pilot flame. Exercise caution when using products with combustible vapors. Always shut- off the gas supply while servicing the stove.

7.CAUTION: DO NOT OPERATE THIS APPLIANCE WITH THE GLASS REMOVED CRACKED OR BRO- KEN. Replacement of the glass should be done by a licensed or qualified service person. Use only replacement glass provided by your authorized Jøtul dealer. Never use any substitute materials.

8.Clean the glass only when necessary. Wipe surface with a clean, dampened, soft cloth. Follow with a dry, soft towel as desired. Take care not to scratch the glass surface.

WARNING: DO NOT USE ABRASIVE CLEANERS ON THE GLASS. NEVER CLEAN THE GLASS WHEN IT IS HOT.

22

Page 22
Image 22
Jotul GF 200 DV manual Operation of Appliance, Correct flame picture