SERVICE (cont.)
ON/OFF WARMER SWITCH
ONE WARMER | |
TWO WARMERS | |
THREE WARMERS | |
FIG. 4 ON/OFF WARMER SWITCH | P1166.45 |
|
Location:
The ON/OFF warmer switch(s) are located on the front of the hood.
Test Procedure:
1.Disconnect the brewer from the power source.
2.Viewing the switch from the back, remove the red wire from the upper terminal and the black wire from the center terminal.
3.With a voltmeter, check the voltage across the red wire and the black wire. Connect the brewer to the power source. The indication must be 220 to 240 volts ac.
4.Disconnect the brewer from the power source.
If voltage is present as described, reconnect the red wire and proceed to #5.
If voltage is not present as described, refer to the Wiring Diagrams and check the brewer wiring har- ness.
5.With the black wire removed, remove the wire from the lower terminal.
6.Check for continuity across the center and lower terminal with the switch in the "ON" (upper) posi- tion. Continuity must not be present when the switch is in the "OFF" (lower) position.
If continuity is present as described, reconnect the black wire to the center terminal and the remaining wire to the lower terminal.
If continuity is not present as described, replace the switch.
Removal and Replacement:
1.Remove the wires from the switch terminals.
2.Remove front end cap.
3.Compress the clips inside the hood and gently push the switch through the opening.
4.Push the new switch into the opening and spread the clips to hold switch in the hood.
5.Reinstall front end cap.
6.Refer to Fig. 5 when reconnecting the wires.
| RED to Terminal Block |
| (Red Insert) |
| BLK to Terminal Block |
| (Black Insert) |
| Terminal #1 (See Chart |
| Below) |
Connect wire to Terminal #1 as follows: | |
Lower Warmer | .................................................. WHI/RED |
Rear Warmer | VIO |
Front Warmer | BRN/BLK |
| P1918 |
FIG. 5 ON/OFF WARMER SWITCH TERMINALS
Page 11