H.Connect steam boiler piping (See Figures 7 thru 10).

1.Burnham V-7 Series steam boiler (Refer to Figure 7).

a.For satisfactory supply of hot water, the V-7 steam boiler must be equipped with a special tapped rear heater coil cover plate contained in both of the following kits:

Part No.

6032702 Includes tapped cover plate, mounting hardware, water temperature limit with well, and installations instructions.

6032703 As above, except less limit and well.

b.The Alliance™ connection labeled "BOILER RETURN" should be piped to tapping "R" (lower left hand ¾" tapping in front of boiler). The use of unions, a shut-off valve, and a drain

valve is recommended for future service convenience. The use of a flow control or check valve is required to prevent back flow through the water heater during operation of the space heating system.

c.The Alliance™ connection labeled "BOILER SUPPLY" should be piped to the 1" NPT tapping in the boiler's aforementioned tapped cover plate. The circulator should be floor mounted with full size 1" piping from the boiler and no flow restrictions in this piping. Be sure the flow arrow on the circulator points toward the water heater. The use of a union, shut-off valves, and a drain valve is recommended for future service convenience. The use of an in- line "Y" style strainer is required to prevent accumulation of sludge in the water heater's coil.

Figure 7

2.Burnham Independence® Series steam boiler (Refer to Figure 8).

a.The Alliance™ connection labeled "BOILER RETURN" should be piped to tapping "M" on the left side of the Independence boiler. The use of unions, a shut-off valve, and a drain valve is recommended for future service convenience. The use of a flow control or check valve is required to prevent back flow through the water heater during operation of the space heating system.

b.The Alliance™ connection labeled "BOILER SUPPLY" should be piped to tapping "N" on the right side of the Independence boiler. The water heater circulator should be floor mounted with full size 1¼" piping from the boiler and no flow restrictions in this piping. Be sure the flow arrow on the circulator points toward the water heater. The use of a union, shut-off valves, and a drain valve is recommended for future service convenience. The use of an in-line "Y" style strainer is required to prevent accumulation of sludge in the water heater's coil.

12

Page 12
Image 12
Burnham AL-26A, 53A, 79A, 40A manual

53A, 40A, 79A, AL-26A specifications

The Burnham line of engineering includes several models known for their efficiency, advanced technology, and adaptability to various applications. Notably, the Burnham 40A, 53A, AL-26A, and 79A are among the most respected in the industry, each offering distinct features tailored to meet the needs of residential and commercial users.

The Burnham 40A is a versatile boiler designed for small to medium-sized applications. One of its main features is its efficient heat exchange system, which maximizes the transfer of heat while minimizing energy consumption. This model incorporates advanced burners that provide uniform heating and enhanced fuel efficiency, ensuring lower operational costs for users. Additionally, it is engineered to be compatible with different fuel types including natural gas and propane, providing versatility and flexibility for installations.

The Burnham 53A, on the other hand, emphasizes durability and reliability. This model is built with a robust steel construction, designed to withstand harsh conditions while maintaining a low maintenance profile. The hybrid design allows for a more significant heat output, making it suitable for larger spaces. Moreover, its integrated control system offers precise temperature management, essential for both comfort and energy savings.

In the portfolio, the AL-26A stands out due to its advanced automation technology. This model features smart control mechanisms that facilitate easy monitoring and adjustments. Users can optimize performance through a user-friendly interface, attracting those who value convenience. Furthermore, the AL-26A has enhanced safety features that ensure reliable operation, reducing the risk of malfunctions.

Finally, the Burnham 79A is a powerhouse, specifically engineered for heavy-duty commercial applications. With high-capacity output, it is capable of meeting demanding heating requirements without sacrificing efficiency. This model incorporates sophisticated insulation technologies that reduce heat loss, thus promoting energy conservation. Its design ensures ease of access for maintenance, thereby extending the lifecycle of the boiler.

In conclusion, the Burnham 40A, 53A, AL-26A, and 79A are exemplary models that reflect the brand's commitment to quality and innovation. Each model boasts unique features and advanced technologies, allowing users to select the best fit for their specific heating needs. As industry leaders, Burnham products continue to set the standard for performance and efficiency in the boiler market.