Cabletron Systems 5000, 5500 Catalyst Stack Ports Table, Possible Port Types Continued, 3-11

Models: 5500 5000, 5500

1 83
Download 83 pages 19.28 Kb
Page 50
Image 50
Catalyst Stack Ports Table

 

 

 

Catalyst Stack System ConÞguration View

 

 

 

 

 

 

 

 

 

 

Catalyst Stack Ports Table

Table 3-4.

Possible Port Types (Continued)

 

 

 

 

 

 

mlt3

 

MLT-3 UTP FDDI

 

 

 

 

 

 

 

sddi

 

STP FDDI

 

 

 

 

 

 

 

smf

 

Single Mode Þber FDDI

 

 

 

 

 

 

 

E10BaseT

 

UTP Ethernet

 

 

 

 

 

 

 

E10BaseF

 

Fiber Ethernet

 

 

 

 

 

 

 

E100BaseTX

 

Fast UTP Ethernet

 

 

 

 

 

 

 

scf

 

Small-connector Þber FDDI

 

 

 

 

 

 

 

 

Status

 

 

 

 

 

Displays the current operational state of this port. Possible states are Other,

 

Ok, MinorFault, and MajorFault.

 

Additional Status

 

Displays an integer representing additional information on the status of this

 

port. Table 3-5provides deÞnitions of the additional status values.

Table 3-5.

Additional Status DeÞnitions

 

 

 

 

 

 

 

Additional

 

DeÞnition

 

Status Value

 

 

 

 

 

 

 

 

 

 

 

0

 

Initial Value, or no activity was detected on the port in the last

 

 

 

polling period.

 

 

 

 

 

1

 

At least one packet was transmitted by the port in the last polling

 

 

 

period. No packets were received and no collisions were detected.

 

 

 

 

 

2

 

At least one packet was received by the port in the last polling

 

 

 

period. No packets were transmitted and no collisions were

 

 

 

detected.

 

 

 

 

 

3

 

At least one packet was transmitted, and at least one packet was

 

 

 

received in the last polling period. No collisions were detected.

 

 

 

 

 

4

 

At least one collision was detected on the port in the last polling

 

 

 

period. No packets were transmitted and no packets were

 

 

 

received.

 

 

 

 

 

5

 

At least one packet was transmitted, and at least one collision

 

 

 

was detected in the last polling period. No packets were received.

 

 

 

 

 

6

 

At least one packet was received, and at least one collision was

 

 

 

detected in the last polling period. No packets were transmitted.

 

 

 

 

 

7

 

At least one packet was transmitted, at least one packet was

 

 

 

received, and at least one collision was detected in the last polling

 

 

 

period.

 

 

 

 

 

 

9032208 E4

ConÞguration Views

 

3-11

Page 50
Image 50
Cabletron Systems 5000, 5500 manual Catalyst Stack Ports Table, Possible Port Types Continued, 3-11, Additional Status