2.1 FPIM MODULE SPECIFICATIONS
This module uses Fiber Port Interface Modules (FPIM) to provide front panel cable connections. The FPIMs are user-installable. See Section 3.2 INSTALLING FPIMS.
2.1.1 FPIM-00 and FPIM-01
The FPIM-00 and FPIM-01 provide a multimode fiber connection. The FPIM-00 uses a MIC style connector and the FPIM-01 uses an SC type connector. The specifications for both devices are listed in Table 2-1.
Table 2-1. FPIM-00 and FPIM-01 Specifications
| | Typical | Worst | Worst | Typical |
| Parameter | Case |
| Value | Case | Budget |
| | Budget |
| | | | |
| | | | | |
| | | | | |
| Receive | -30.5 dBm | -28.0 dBm | — | — |
| Sensitivity | | | | |
| | | | | |
| Peak Input | -7.6 dBm | -8.2 dBm | — | — |
| Power | | | | |
| | | | | |