CHAPTER 2
NETWORK REQUIREMENTS
Before installing Cabletron Systems 7F06-02 Module, review the network requirements outlined in this chapter. All requirements included in this chapter should be met to ensure satisfactory performance of the 7F06-02 Module. Failure to do so may result in unsatisfactory network performance.
Appendix A
2.1 FPIM MODULE SPECIFICATIONS
This module uses Fiber Port Interface Modules (FPIM) to provide front panel cable connections. The FPIMs are user-installable. See Section 3.2 INSTALLING FPIMS.
2.1.1 FPIM-00 and FPIM-01
The FPIM-00 and FPIM-01 provide a multimode fiber connection. The FPIM-00 uses a MIC style connector and the FPIM-01 uses an SC type connector. The specifications for both devices are listed in Table 2-1.
Table 2-1. FPIM-00 and FPIM-01 Specifications
|  |   | Typical | Worst | Worst | Typical | 
|  | Parameter | Case | 
|  | Value | Case | Budget | 
|  |   | Budget | 
|  |   |   |   |   | 
|  |   |   |   |   |   | 
|  |   |   |   |   |   | 
|  | Receive | -30.5 dBm | -28.0 dBm | — | — | 
|  | Sensitivity |   |   |   |   | 
|  |   |   |   |   |   | 
|  | Peak Input | -7.6 dBm | -8.2 dBm | — | — | 
|  | Power |   |   |   |   | 
|  |   |   |   |   |   |