2-2
NETWORK REQUIREMENTS
Transmitter power parameters are listed in Table 2-2.
The link distance is up to 2 kilometers on the multimode fiber-
optic cable as specified by ANSI MMF-PMD.
Table 2-2. Transmitter Power Parameters
Parameter Typical
Value
Worst
Case
Worst
Case
Budget
Typical
Budget
50/125
µ
m
fiber -13.0 dBm -15.0 dBm 13.0 dB 17.5 dB
62.5/125
µ
m fiber -10.0 dBm -12.0 dBm 16.0 dB 20.5 dB
100/140
µ
m fiber -7.0 dBm -9.0 dBm 19.0 dB 23.5 dB
Error Rate Better than
10
-10