2.3NETWORK CONNECTIONS

The VHSIM-G02 has two RJ45 connectors for the Gigabit Ethernet connections, Port 1 and Port 2. The cable used for connections is 4-pair Category 5 Unshielded Twisted Pair, conforming to the IEEE 802.3ab specification. The maximum distance supported is 100 meters. Refer to Appendix A for the pin assignments for the RJ45 port.

NOTE

The VHSIM-G02’s Gigabit Ethernet front panel ports support Category 5 Unshielded Twisted Pair (UTP) cabling with an impedance between 85 and 111 ohms.

Connect a twisted pair segment to the Gigabit Ethernet port on the VHSIM-G02 as follows:

1.Ensure that the device connected to the other end of the segment is powered ON.

2.Connect the twisted pair segment to the VHSIM-G02 by inserting the RJ45 connector on the twisted pair segment directly into the RJ45 port as shown in Figure 2-3.

.

VHSIM-G02

1

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4001_01

Figure 2-3 Connecting a Twisted Pair Gigabit Ethernet Segment