Cadence MONO CLASS D manual Boom, Harder, MONO BRIDGING 2 AMPLIFIERS INTO 1 WOOFER, Ground

Models: MONO CLASS D

1 16
Download 16 pages 62.77 Kb
Page 10
Image 10
MONO BRIDGING 2 AMPLIFIERS INTO 1 WOOFER

10

MONO BRIDGING 2 AMPLIFIERS INTO 1 WOOFER

 

 

MASTER/SLAVE CONNECTION DIAGRAM

Mode switch

IMPORTANT:

Link between 2 amplifier

Ground

- speaker terminals

#14 minimum

 

BURSTPR

POWER

2 ohm

FULL POWER

minimum

LEVEL

-50 dB POWER

BATTERY

VOLTAGE

FULL

Pm2

 

Mode switch

Cable

 

Distribution

block

Master fuse

at battery

NOTES ON MONO BRIDGING 2 RS AMPLIFIERS INTO ONE SPEAKER LOAD MASTER/SLAVE CONNECTION DIAGRAMGroundNOTES ON MONO BRIDGING 2 RS AMPLIFIERS INTO ONE SPEAKER LOAD  Ground GroundAMPLIFIER MODE SWITCH, INPUTS AND REMOTE CONTROL

Battery

Boom

Harder!

Set the AMPLIFIER MODE switches as shown

Connect the source to the master amplifier inputs, and an optional CPR remote control to the master, as shown.

Use a PM2 bridging cable to connect the master output of the first amplifier to the slave input of the second.

Connect the speaker as shown, with the link between the negative speaker terminals of the two amplifiers.

Connect the ground terminal with as short a piece of cable as possible to the nearest metal chassis point.

Mount a master fuse right at the battery + terminal as shown. Add up the current draw for all amplifiers in the system to determine the rating for this fuse. Use a power distribution block, such as the Cadence FH-1, FH-2 or FH-3 at the amplifier location to supply +12 volt to each amplifier.

Connect the remote turn on signal from the source to all amplifier remote turn on terminals.

Page 10
Image 10
Cadence MONO CLASS D manual Boom, Harder, MONO BRIDGING 2 AMPLIFIERS INTO 1 WOOFER, Master/Slave Connection Diagram, Ground