Natural Gas
Requirements
The installation of this appliance must conform with local codes or, in the absence of local codes, to the national fuel gas code, ANSI
A licensed contractor or local gas company representative must per- form all natural gas connections.
Ensure that the service supplying the side burner is fitted with a shut off valve conveniently positioned near the side burner and giving ease of access.
The side burner must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 0.5 psi (3.5 kPa).
The side burner and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressure in excess of 0.5 psi (3.5 kPa).
Connection
1.Slide the side burner forward to gain access to the gas connection point in the rear.
2.Connect a suitable flex connector to the gas connection point.
3.Check the side burner controls to ensure all control valves are in the full OFF position.
4.Turn on the main gas supply and check all connections for leaks using soapy water as described in the leak testing procedure sec- tion.
Warning: If you see bubbles in the soapy solution at any of the connec- tions, turn off the gas supply and tighten the connection. If tightening the connection does not seal the leak, it may be necessary to replace
the flex hose.
Cal Flame Side Burners
9
Installation / Assembly
LTR50001082, Rev. B | www.calspas.com |