Xantrex Technology XHR, XFR, XFR3 Features and Specifications, Models, 7.5-140, 12-100, 20-60

Models: XHR, XFR, XFR3

1 62
Download 62 pages 62.83 Kb
Page 15
Image 15
Specifications

Features and Specifications

Specifications

Specifications

The specifications in this section are warranted at 25°C ±5°C unless otherwise specified. All specifications are subject to change without notice.

Table 1.1 Specifications for XFR 1200 W Series Supply with GPIB Interface Installed (7.5 V to 40 V)

Models

7.5-140

12-100

20-60

35-35

40-30

Program Resolution

 

 

 

 

 

Voltage

1.16mV

1.8mV

3.08mV

5.4mV

6.2mV

Current

19.6mA

14mA

8.4mA

5.4mA

4.2mA

OVP

1.16mV

1.8mV

3.08mV

5.4mV

6.2mV

Program Accuracy1

10mV

50mV

75mV

75mV

75mV

Voltage

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.3%

Current

500mA

460mA

250mA

200mA

150mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.15%

OVP

80mV

150mV

200mV

350mV

400mV

Readback Resolution

 

 

 

 

 

Voltage

1.16mV

1.8mV

3.08mV

5.4mV

6.2mV

Current

19.6mA

14mA

8.4mA

5.4mA

4.2mA

Readback Accuracy1

 

 

 

 

 

Voltage

30mV

60mV

75mV

75mV

75mV

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.3%

Current

500mA

460mA

250mA

200mA

150mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.15%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model 20-60 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.

Release 3.1

13

Page 15
Image 15
Xantrex Technology XHR, XFR, XFR3 manual Features and Specifications, Models, 7.5-140, 12-100, 20-60, 35-35, 40-30