Xantrex Technology XHR, XFR, XFR3 Cmode, Idata, Ihi, Ilo, Irdat, Irhi, Irlo, Ovcal, Vdata, Vhi

Models: XHR, XFR, XFR3

1 62
Download 62 pages 62.83 Kb
Page 44
Image 44

Operation

Command Summary

Table 3.7

Calibration Commands

Command

Description

 

 

CMODE

Places the supply into calibration mode.

 

 

IDATA

Calculates the slope and intercept for current programming.

 

 

IHI

Sets the current output to the high calibration point.

 

 

ILO

Sets the current output to the low calibration point.

 

 

IRDAT

Calculates the slope and intercept for current readback.

 

 

IRHI

Sets the current output to the high readback point.

 

 

IRLO

Sets the current output to the low readback point.

 

 

OVCAL

Calibrates the over voltage protection (OVP).

 

 

VDATA

Calculates the slope and intercept for voltage programming.

 

 

VHI

Sets the voltage output to the high calibration point.

 

 

VLO

Sets the voltage output to the low calibration point.

 

 

VRDAT

Calculates the slope and intercept for voltage readback.

 

 

VRHI

Sets the voltage output to the high readback point.

 

 

VRLO

Sets the voltage output to the low readback point.

 

 

Table 3.8

Status Commands

Command

Description

 

 

ASTS?

Asks for the supply’s accumulated status register.

 

 

FAULT?

Asks for the supply’s fault register for the status preset operating

 

conditions.

MASK

Prevents the supply's previously unmasked operating conditions from

 

setting bits in the fault register.

 

 

STS?

Asks for the supply’s present status register.

 

 

UNMASK

Enables you to select those supply's operating conditions that you are

 

most interested in monitoring for fault occurrence.

 

 

UNMASK?

Asks for the supply's fault conditions which are currently enabled

 

(unmasked).

42

Operating Manual for GPIB for XHR/XFR Series Power Supply

Page 44
Image 44
Xantrex Technology XHR, XFR, XFR3 Cmode, Idata, Ihi, Ilo, Irdat, Irhi, Irlo, Ovcal, Vdata, Vhi, Vlo, Vrdat, Vrhi, Vrlo