Xantrex Technology XHR, XFR, XFR3 Features and Specifications, Models, 100-10, 150-7, 300-3.5

Models: XHR, XFR, XFR3

1 62
Download 62 pages 62.83 Kb
Page 20
Image 20
100-10

Features and Specifications

Specifications

Table 1.6 Specifications for XHR 1000 W Series Supply with GPIB Interface Installed (100 V to 600 V)

Models

100-10

150-7

300-3.5

600-1.7

Program Resolution

15.4mV

23.1mV

46.2mV

92.4mV

Voltage

Current

3.92mA

2.52mA

1.26mA

0.56mA

OVP

15.4mV

23.1mV

46.2mV

92.4mV

Program Accuracy1

 

 

 

 

Voltage

150mV

225mV

225mV

250mV

 

±0.35%

±0.35%

±0.35%

±0.35%

Current

140mA

120mA

80mA

80mA

 

±0.15%

±0.1%

±0.1%

±0.1%

OVP

800mV

1.5V

3.0V

6V

Readback Resolution

 

 

 

 

Voltage

15.4mV

23.1mV

46.2mV

92.4mV

Current

3.92mA

2.52mA

1.26mA

0.56mA

Readback Accuracy1

 

 

 

 

Voltage

150mV

225mV

225mV

250mV

 

±0.35%

±0.35%

±0.35%

±0.35%

Current

140mA

120mA

80mA

80mA

 

±0.15%

±0.1%

±0.1%

±0.1%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model 20-50 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 50mV ± 0.12% of the set voltage of 10 volts.

18

Operating Manual for GPIB for XHR/XFR Series Power Supply

Page 20
Image 20
Xantrex Technology XHR, XFR, XFR3 manual Features and Specifications, Models, 100-10, 150-7, 300-3.5, 600-1.7