Xantrex Technology XHR, XFR, XFR3 Serial Poll In a serial poll, the controller polls each device

Models: XHR, XFR, XFR3

1 62
Download 62 pages 62.83 Kb
Page 38
Image 38
Serial Poll In a serial poll, the controller polls each device.

Operation

GPIB Operation

Service Service request is a uniline message asserted by the power supply at power on and Request for fault conditions. Ten (10) power supply conditions are defined as faults: CV, CC, OV, OTP, SD, FOLD, ERR, ACF, OPF, and SNSP. See “Accumulated Status, Status, and Fault Registers” on page 50 for more information. Power ON (PON) can also be

flagged in the fault register if the supply's rear panel power on service request (PON SRQ) switch is set to ON. See “Power On Service Request (PON SRQ)” on page 25.

Enabling or disabling a condition from asserting service request does not affect the condition within the power supply, nor the external status indicators.

Serial Poll In a serial poll, the controller polls each device.

Example:

ibrsp

Return serial poll byte.

The power supply responds with a 8-bit status byte defined as follows:

Table 3.2 Serial Poll Status Register

Bit

Decimal

Description

Reset By

Position

Weight

 

 

0

(LSB)

1

Fault - Set when any bit in the fault

FAULT? query to reset

 

 

 

register is set by a fault condition in the

 

 

 

 

supply. See also “Accumulated

 

 

 

 

Status, Status, and Fault Registers”

 

 

 

 

on page 50.

 

1

 

2

Not used

 

 

 

 

 

 

2

 

4

Not used

 

 

 

 

 

 

3

 

8

Not used

 

 

 

 

 

 

4

 

16

Ready - Set when power supply is

Power supply, during

 

 

 

ready to accept commands.

command processing

 

 

 

 

period

5

 

32

Error (ERR) - Set when ERR bit

ERR? query

 

 

 

asserted in status register. See also

 

 

 

 

“Accumulated Status, Status, and

 

 

 

 

Fault Registers” on page 50.

 

6

 

64

Request Service (SRQ) - Set when

Serial Poll

 

 

 

power supply requests service.

 

7

(MSB)

128

Power On (PON) - Set when unit

CLR or Device Clear

 

 

 

initializes at power on.

 

36

Operating Manual for GPIB for XHR/XFR Series Power Supply

Page 38
Image 38
Xantrex Technology XHR, XFR, XFR3 manual Serial Poll In a serial poll, the controller polls each device, Example