Features and Specifications

Specifications

Table 1.2 Specifications for XFR 1200 W Series Supply with GPIB Interface Installed (60 V to 600 V)

Models

60-20

100-12

150-8

300-4

600-2

Program Resolution

9.2mV

15.4mV

23.1mV

46.2mV

92.4mV

Voltage

Current

2.8mA

1.68mA

1.12mA

0.56mA

0.28mA

OVP

9.2mV

15.4mV

23.1mV

46.2mV

92.4mV

Program Accuracy1

 

 

 

 

 

Voltage

150mV

150mV

225mV

225mV

250mV

 

±0.25%

±0.35%

±0.35%

±0.35%

±0.35%

Current

120mA

80mA

80mA

80mA

50mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

OVP

600mV

800mV

1.5V

3.0V

6V

Readback Resolution

 

 

 

 

 

Voltage

9.2mV

15.4mV

23.1mV

46.2mV

92.4mV

Current

2.8mA

1.68mA

1.12mA

0.56mA

0.28mA

Readback Accuracy1

 

 

 

 

 

Voltage

150mV

150mV

225mV

225mV

250mV

 

±0.25%

±0.35%

±0.35%

±0.35%

±0.35%

Current

120mA

80mA

80mA

80mA

50mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model 20-60 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.