Installation and Configuration

User Signals

Figure 2.5

J7 User Signal Connector Circuit Block Diagram

J7 Cable Use a standard 8-position telephone jack and data cable to connect to J7. Add a Connection ferrite block to reduce radiated emission. The one inch square ferrite block with

built-in housing clip is packaged and shipped with the power supply interface card.

To install the ferrite block:

1.Position the block no more than 5 cm (2") from the power supply end of the J7 user cable.

2.Open the ferrite block housing.

3.Loop the cable through the ferrite block. See Figure 2.6, “J7 User Cable with Ferrite Block” on page 32.

4.Close the housing clip.

The ferrite block ensures that the power supply system meets radiated emission requirement 89/336/EEC for CE mark approval. See the power supply's operating manual for noise specifications.