Cal Spas 6300 Electronic Control Operation, Initial Start-up, Time, Modes, Operating Your Spa

Models: 6200 5100 6300

1 52
Download 52 pages 12.14 Kb
Page 15
Image 15
9800 Electronic Control Operation

Operating Your Spa

9800 Electronic Control Operation

When first powered up, the 9800 electronic system will perform a self-diagnostic check and then it will automatically heat to and maintain a temperature of 100°F (37.5°C) until you change the set temperature as listed in the “Temperature Adjustment” section below.

These instructions will describe features and options that your particular spa may not be equipped with.

Initial Start-up

When your spa is first powered up, it displays some

Standard Mode: This is programmed to maintain the

configuration codes and then goes into priming mode

desired temperature. Note that the last measured spa

(Pr will appear on the display panel). This mode lasts up

temperature displayed is current only when the pump

to four minutes and then the spa begins to heat to its pre

has been running for at least two minutes. The “STAND”

-programmed temperature of 100°F.

icon will display until the mode is changed.

Temperature Adjustment

Economy Mode: Economy mode heats the spa to the

set temperature only during filter cycles. The “ECON”

 

(Range 80°F to 104°F, 26°C to 40°C)

icon will display until the mode is changed. Pressing the

The start-up temperature is set at 100°F (37.5°C). The

“JETS 1” button while in economy mode puts the spa in

last measured temperature is constantly displayed

standard-in-economy mode, which operates the same

on the control panel. Note that the last measured spa

as standard mode but reverts back to economy mode

temperature is displayed. The displayed temperature

automatically after one hour. During this time, pressing

will be updated when the pump has been running for at

the “MODE/PROG” button will revert to economy mode

least two minutes.

immediately.

Press the “UP” or “DOWN” buttons once to display the

Sleep Mode: Sleep mode heats the spa to within 20°F

(11°C) of the set temperature only during filter cycles. The

set temperature. Each time either button is pressed

“SLEEP” icon will display until the mode is changed.

again, the set temperature will increase or decrease

Standby Mode: Pressing “Warm” or “Cool” then “JETS

depending on which button is pressed. After three

seconds, the control panel will automatically display the

2” will turn off all spa functions temporarily. This is helpful

last measured spa temperature.

when changing a filter. Pressing any button resets the

Time

spa.

Jets 1

When time hasn’t been programmed, the “TIME” icon

flashes. To set the time, press the “TIME” button and

Press the “JETS 1” button once to turn pump 1 on or off

then the “MODE/PROG” button. Use the “UP” and

and to shift between low and high speeds if equipped.

“DOWN” buttons to adjust time. See the next page for

If left running, the low speed turns off after two hours

more detailed instructions.

and the high speed turns off after 15 minutes. On non-

Standard, Economy, Sleep, and Standby

circulation systems, the low speed of pump 1 runs when

the blower or any other pump is on. It may also activate

Modes

for at least two minutes every 30 minutes to detect the

Mode/Prog: This button is used to switch between

spa temperature and then to heat to the set temperature if

needed, depending upon the mode. When the low speed

standard, economy, and sleep modes.

turns on automatically, it cannot be deactivated from the

 

1.Press “MODE/PROG” to enter mode programming. panel; however, the high speed may be started.

2.Press the “DOWN” button to cycle through to the desired mode.

3.Press “MODE/PROG” to confirm selection.

2008 Portable Spa Owner’s Manual

Page 13

LTR20081000, Rev. B

Page 15
Image 15
Cal Spas 6300 Electronic Control Operation, Initial Start-up, Time, Standard, Economy, Sleep, and Standby, Modes, Jets