Operating SpaYour
the Up or Down button again to change the filtering cycle duration. When desired duration is selected press the Jets button to exit.
The low speed pump will run for the duration of the filtering cycle and if an ozone system is installed it will be activated. During filtering, FC will appear on the main display.
Diagnostic Messages
Message | Meaning | Action Required |
|
|
|
No message | 1) Spa temperature is unknown. | 1) After pump has been running for 2 minutes tem- |
on display |
| perature will be displayed. |
| 2) Spa is in Economy or Sleep | 2) In Economy or Sleep mode, the pump may be off |
| mode. | for hours outside a filter cycle. If you wish to see the |
|
| current spa temperature, either switch to Standard |
|
| mode or turn Jets1 on for at least two minutes. |
| 3) Power has been cut off to the | 3) The control panel will be disabled until power re- |
| spa. | turns. Spa settings and time of day will be preserved |
|
| for 30 days with a battery |
|
|
|
dr | Insufficient water detected in | Check water level in spa. Refill if necessary. Make |
| heater. Spa will be shut down for | sure pumps are been primed and filter cartridges are |
| 15 minutes. | clean. Press any button to reset or wait 15 minutes |
|
| and spa will automatically reset. If message spa does |
|
| not reset, call your dealer or service organization. |
drY | Insufficient water detected in | Follow directions for dr message and press any button |
| heater. Spa is shut down. | to reset spa. Spa will not automatically reset when dry |
| (Displays on third occurrence of dr | or dY is displayed. |
|
| |
| message.) |
|
|
|
|
Ec | Indicates heater is in Economy | None. |
| Mode. |
|
|
|
|
Temperature unknown | After the pump has been running for two minutes, the | |
|
| temperature will be displayed. |
|
|
|
HFL | A difference in readings between | Make sure spa is filled to proper level and that pumps |
| temperature sensors has been | are primed and filter cartridges are clean. If message |
| detected indicating a possible water | does not reset, call your dealer or service organiza- |
| flow problem. | tion. |
|
|
|
ICE | Potential freeze condition detected. | No action required. The pumps and the blower will |
|
| automatically activate regardless of spa status. |
|
|
|
LF | Persistent low flow problems. | Follow action required for HL or HFL message. Heat- |
| Heater is shut down, but other spa | ing capacity of the spa will not reset automatically. |
| functions continue to run normally. | Press any button to reset. |
| Displays on the fifth occurrence of |
|
| the HL or HFL message within 24 |
|
| hours. |
|
|
|
|
OHS | Overheat protection. The spa has | DO NOT ENTER THE WATER. Remove the spa cover |
| shut down. One of the sensors | and allow water to cool. At 107°F, the spa should |
| has detected that the spa water is | automatically reset. If spa does not reset, shut off |
| 110°F. | the power to the spa and call your dealer or service |
|
| organization. |
|