20

Spa

Electrical and Electronic Connection

Preparing forYour New Inground

Remote Equipment Topside Control Panel

The next few steps to complete the installation should be performed along with installation of the tempera- ture sensor and 12V spa light wiring (if applicable). All of these components are generally installed using the same conduit.

1.Locate the topside control panel extension loom in the control box mounted with the equipment pack. This extension loom and attached black ter- minal connector (see figure at right) will be used to connect the topside control panel to the control box.

2.Connect one end of the black terminal connector to the topside control panel cable.

3.Connect the other end of the terminal connector to the extension loom.

NOTE: This connection must be kept dry. We recom- mend that a waterproof junction box be used in instal- lations where moisture could penetrate this terminal connector.

4.Lay out the extension loom to verify that you have enough length to reach the control box. Remem- ber that conduit runs are not generally run in a straight line. Every bend, and up and down run consumes line length. Take this into consideration when verifying electrical and plumbing runs.

5.Connect the extension loom to the control panel location on the circuit board located inside the control box. You will also need to connect both the temperature and high limit sensors to the cir- cuit board prior to testing. (See the temperature and high limit installation instruction on the next page for proper identification and see the wiring diagram on the inside cover of the control box for proper placement.)

6.Turn on the power supply to the spa equipment and briefly test all functions on the topside control panel to verify that both connections and exten- sion loom are in working order before proceeding with the installation.

NOTE: Circuit board programming will not allow spa operation without both the temperature and high limit sensors being properly connected to the circuit board.

7.Once topside panel operation is verified. Turn off power, disconnect the extension loom from the circuit board and GENTLY route through conduit to complete installation.

NOTE: This loom and its connector are not meant to withstand heavy pulling. Make sure, when routing the extension loom and temperature sensor lines through conduit, you exercise extreme caution.

Once properly run through the conduit, repeat steps 5 and 6 above.

Inground Spas

www.calspas.com

LTR20111002, Rev. A

Page 20
Image 20
Cal Spas LTR20111002 manual Electrical and Electronic Connection, Preparing forYour New Inground