Caldera Highland Series Spa Troubleshooting, General Operation Troubleshooting Guide, Problem

Models: Highland Series

1 32
Download 32 pages 60.85 Kb
Page 28
Image 28
SPA TROUBLESHOOTING

SPA TROUBLESHOOTING

If your spa doesn’t seem to be working the way you believe it should, please review the “START-UP” and “OPERATION” instructions in this manual. If this doesn’t help you correct the problem, follow the appropriate instructions below. If the problem still is not resolved, call your Caldera® dealer.

GENERAL OPERATION TROUBLESHOOTING GUIDE

 

 

 

 

Problem

Probable causes

Solutions

Entire spa is inoperative

Power failure / not plugged in

• Check power source

For high limit,display shows

GFCI tripped

• Reset GFCI; call for service if it will not reset.

“_ _ _ _

Heater high-limit thermostat tripped

• Disconnect power for at least thirty seconds to reset heater high limit. If it

_ _ _ _”

 

 

will not reset, check for clogged filter. If tripping continues, call for service.

 

 

 

 

Spa does not heat; jets and

Pressure switch tripped

• Check for clogged filter. The pressure switch will reset when the flow of

light operate

 

 

 

 

water through the heater has been restored. Call for service if the pressure

(Display shows

 

 

 

 

switch trips frequently.

“_ _ _ _ or _._._._

 

 

 

 

 

_ _ _ _ _ ._._._”

 

 

 

(Display shows “_._._._

Pressure switch senses flow through heater

• Contact an Authorized Service Technician

_._._._”)

 

even though the jet pump is off

 

 

 

 

 

 

 

 

Jets weak or surging

• Spa water level too low

• Add water

• Clean filters / Clean suction screens

 

• Filters clogged / suction screens clogged

 

• Open jet nozzles / Open air valve

 

• Jet nozzles closed / Air valve closed

 

 

Light inoperative

Bad connection

• Contact an Authorized Service Technician

 

 

 

 

 

 

 

Display shows “- - - -

• Heater high limit thermostat tripped

• Disconnect power to the spa for at least thirty seconds to reset the heater

- - - -”

high-limit. If tripping continues, clean the filter, then if tripping still occurs,

 

 

(Entire spa inoperative)

 

 

call for service.

Water temperature

System Controls

• Contact an Authorized Service Technician

significantly different from

 

 

 

 

display temperature.

 

 

 

Display shows flashing

 

 

 

“READY” icon

 

 

 

 

 

 

 

Priming the pump(s): Upon filling or refilling the spa, if a pump is operating and water is not flowing from any of its jets, the pump may not be properly primed. To correct, perform the following procedures:

Turn off power to the spa at the breaker and remove the equipment compartment door (as seen on page 24).

Loosen the union on the top of the pump(s) (as seen on page 24) to allow the air to escape, the hand-tighten the union(s).

Turn power back on, activate the pump and check to make sure union is tight enough to keep it from leaking. Re-install pump and equipment doors.

25

Page 28
Image 28
Caldera Highland Series Spa Troubleshooting, General Operation Troubleshooting Guide, Problem, Probable causes, Solutions