Operating Instructions and Parts List | PW1350 |
|
|
System Connection
1. | Insert lance into the gun and turn |
| clockwise to positive stop as shown |
| in Figure 5. |
Figure 5 - Gun/Lance Connection | |
2. | Be sure that the power switch is in |
| the “OFF” position. |
3. | Attach the high pressure hose onto |
| the pump water outlet by turning |
| clockwise and hand tightening. Be |
| certain to push hose onto pump |
| while tightening. Be careful to not |
| cross thread the hose. |
4. | Connect garden hose as explained |
| under Garden Hose Connection |
| Instructions. |
5. | Plug the power cord into a |
| grounded 120V outlet. |
6. | Turn water on. |
7. | Unlock trigger lock by moving lock |
| right to left. |
8. | Depress and hold the trigger on |
| the gun for one minute to release |
| pressure and remove any air trapped |
| in the system. |
9. | Turn the “ON/OFF” switch to the |
| “ON” position, while pulling the |
| trigger. |
ON OFF
Figure 6 - ON/OFF Switch
How to Avoic Damaging Surfaces
Directions for Use
Damage to cleaning surfaces occurs because the impact force of the water exceeds the durability of the surface. You can vary the impact force by controlling the nozzle’s fan pattern, the nozzle’s angle to the cleaning surface, and the nozzle’s distance from the cleaning surface. Never use a narrow high impact stream or a turbo nozzle on a surface that is susceptible to damage. Avoid spraying windows with a narrow high impact stream or turbo nozzle. Doing so may break the window. The surest way to avoid damaging surfaces is to follow these steps:
1.Before triggering the gun, adjust the nozzle to a wide fan pattern.
2.Place the nozzle approximately
3.Vary the fan pattern spray angle and the distance to the cleaning surface until optimum cleaning efficiency
is achieved without damaging the surface.
Nozzle Cleaning Instruction
A clogged or partially clogged nozzle can cause a significant reduction of water coming out of the nozzle and cause the unit to pulsate while spraying.
To clean out the nozzle:
•Turn off unit.
•Turn off water supply. Relieve any pressure trapped in the hose by squeezing trigger
www.chpower.com6