Campbell Hausfeld IN468001AV System Connection, How to Avoic Damaging Surfaces, Instructions

Models: IN468001AV

1 36
Download 36 pages 20.87 Kb
Page 6
Image 6
System Connection

Operating Instructions and Parts List

PW1350

 

 

System Connection

1.

Insert lance into the gun and turn

 

clockwise to positive stop as shown

 

in Figure 5.

Figure 5 - Gun/Lance Connection

2.

Be sure that the power switch is in

 

the “OFF” position.

3.

Attach the high pressure hose onto

 

the pump water outlet by turning

 

clockwise and hand tightening. Be

 

certain to push hose onto pump

 

while tightening. Be careful to not

 

cross thread the hose.

4.

Connect garden hose as explained

 

under Garden Hose Connection

 

Instructions.

5.

Plug the power cord into a

 

grounded 120V outlet.

6.

Turn water on.

7.

Unlock trigger lock by moving lock

 

right to left.

8.

Depress and hold the trigger on

 

the gun for one minute to release

 

pressure and remove any air trapped

 

in the system.

9.

Turn the “ON/OFF” switch to the

 

“ON” position, while pulling the

 

trigger.

ON OFF

Figure 6 - ON/OFF Switch

How to Avoic Damaging Surfaces

Directions for Use

Damage to cleaning surfaces occurs because the impact force of the water exceeds the durability of the surface. You can vary the impact force by controlling the nozzle’s fan pattern, the nozzle’s angle to the cleaning surface, and the nozzle’s distance from the cleaning surface. Never use a narrow high impact stream or a turbo nozzle on a surface that is susceptible to damage. Avoid spraying windows with a narrow high impact stream or turbo nozzle. Doing so may break the window. The surest way to avoid damaging surfaces is to follow these steps:

1.Before triggering the gun, adjust the nozzle to a wide fan pattern.

2.Place the nozzle approximately 4-5 feet away from the cleaning surface. Then hold the nozzle at a 45° angle to the cleaning surface. Trigger the gun.

3.Vary the fan pattern spray angle and the distance to the cleaning surface until optimum cleaning efficiency

is achieved without damaging the surface.

Nozzle Cleaning Instruction

A clogged or partially clogged nozzle can cause a significant reduction of water coming out of the nozzle and cause the unit to pulsate while spraying.

To clean out the nozzle:

Turn off unit.

Turn off water supply. Relieve any pressure trapped in the hose by squeezing trigger 2-3 times.

www.chpower.com6

Page 6
Image 6
Campbell Hausfeld IN468001AV System Connection, How to Avoic Damaging Surfaces, Nozzle Cleaning Instruction, Instructions