Operating Instructions | Model JB004250 |
●Ensuring that tools which require repair are not further used before repair. Tags and physical segregation are recommended means of control.
Danger indicates
an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
●Read and understand tool labels and manual. Failure to follow warnings, dangers, and cautions could result in DEATH or SERIOUS INJURY.
● Do not use any type of reactive gases, including, but not
limited to, oxygen and combustible gases, as a power
source. Use filtered, lubricated, regulated compressed air only. Use of a reactive gas instead of compressed air may cause the tool to explode which will cause death or serious personal injury.
●Use only a pressure- regulated
compressed air source to limit the air pressure supplied to
the tool. The
regulated pressure must not exceed 100 psi. If the regulator fails, the pressure delivered to the tool must not exceed 200 psi. The tool could explode which will cause death or serious personal injury.
●Never use gasoline
or other flammable
liquids to clean the tool. Never use the
tool in the presence
of flammable liquids or gases. Vapors could ignite by a spark and cause an explosion which will result in death or serious personal injury.
●Always remain in
a firmly balanced position when using or handling the tool.
●Do not remove, tamper with, or
otherwise cause the Work Contact Element (WCE) or
trigger to become
inoperable. Do not operate any tool which has been modified in a like fashion. Death or serious personal injury could result.
●Do not touch the
trigger unless driving fasteners. Never attach air
line to tool or carry tool while touching the
trigger. The tool could eject a fastener which will result in death or serious personal injury.
Warning indicates
a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
●Always disconnect the tool from the power source when unattended,
performing any maintenance or repair, clearing a jam, or moving the tool to a new location. Always reconnect the air line BEFORE loading any fasteners. Do not load the tool with fasteners when either the trigger is depressed or the Work Contact Element (WCE) is engaged. The tool could eject a fastener causing death or serious personal injury.
●Always fit tool with a fitting
or hose coupling on or
near the tool in such a manner
that all compressed air in the tool is discharged at the time the fitting or hose coupling is disconnected. Do not use a check valve or any other fitting which allows air to remain in the tool. Death or serious personal injury could occur.
●Never place hands or any other body parts in the fastener discharge area of the tool. The tool might eject a fastener and
could result in death or serious personal injury.
Nailer Components And Specifications
Adjustable
Exhaust
Reload Indicator
•REQUIRES: 0.4 SCFM with 10 nails per minute @ 90 psi
•AIR INLET: 1/4 inch NPT
•NAIL SIZE RANGE: 3/8 inch to 2 inch
•MAGAZINE CAPACITY:
100 Nails per load, 18 gauge
•WEIGHT: 3 lbs., 7 oz.
•LENGTH: 10 1⁄8 inch
•HEIGHT: 9 1⁄2 inch
•MAXIMUM PRESSURE: 100 psi
•PRESSURE RANGE:
Trigger
Magazine
Adjustable
Depth
Control
Quick Clear
Nose
Work Contact |
| Magazine |
Element (WCE) |
| Latch |
| Nail Loading Area | Button |
|
| |
Nail Discharge Area |
|
|
www.chpower.com