General Safety Information (Continued)

Ensuring that tools which require repair are not further used before repair. Tags and physical segregation are recommended means of control.

Danger indicates

an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.

Read and understand tool labels and manual. Failure to follow warnings, dangers, and cautions could result in DEATH or SERIOUS INJURY.

Do not use any type of reactive gases, including, but not

limited to, oxygen and combustible gases, as a power

source. Use filtered, lubricated, regulated compressed air only. Use of a reactive gas instead of compressed air may cause the tool to explode which will cause death or serious personal injury.

Use only a pressure- regulated

compressed air source to limit the air pressure supplied to

the tool. The

regulated pressure must not exceed 100 psi. If the regulator fails, the pressure delivered to the tool must not exceed 200 psi. The tool could explode which will cause death or serious personal injury.

Never use gasoline

or other flammable

liquids to clean the tool. Never use the

tool in the presence

of flammable liquids or gases. Vapors could ignite by a spark and cause an explosion which will result in death or serious personal injury.

Always remain in

a firmly balanced position when using or handling the tool.

Do not remove, tamper with, or

otherwise cause the Work Contact Element (WCE) or

trigger to become

inoperable. Do not operate any tool which has been modified in a like fashion. Death or serious personal injury could result.

Do not touch the

trigger unless driving fasteners. Never attach air

line to tool or carry tool while touching the

trigger. The tool could eject a fastener which will result in death or serious personal injury.

Warning indicates

a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.

Always disconnect the tool from the power source when unattended,

performing any maintenance or repair, clearing a jam, or moving the tool to a new location. Always reconnect the air line BEFORE loading any fasteners. Do not load the tool with fasteners when either the trigger is depressed or the Work Contact Element (WCE) is engaged. The tool could eject a fastener causing death or serious personal injury.

Always fit tool with a fitting

or hose coupling on or

near the tool in such a manner

that all compressed air in the tool is discharged at the time the fitting or hose coupling is disconnected. Do not use a check valve or any other fitting which allows air to remain in the tool. Death or serious personal injury could occur.

Never place hands or any other body parts in the fastener discharge area of the tool. The tool might eject a fastener and

could result in death or serious personal injury.

Nailer Components And Specifications

Adjustable

Exhaust

Reload Indicator

REQUIRES: 0.4 SCFM with 10 nails per minute @ 90 psi

AIR INLET: 1/4 inch NPT

NAIL SIZE RANGE: 3/8 inch to 2 inch

MAGAZINE CAPACITY:

100 Nails per load, 18 gauge

WEIGHT: 3 lbs., 7 oz.

LENGTH: 10 18 inch

HEIGHT: 9 12 inch

MAXIMUM PRESSURE: 100 psi

PRESSURE RANGE: 60-100 psi

Trigger

Magazine

Adjustable

Depth

Control

Quick Clear

Nose

Work Contact

 

Magazine

Element (WCE)

 

Latch

 

Nail Loading Area

Button

 

 

Nail Discharge Area

 

 

www.chpower.com