Page 4
Image 4
0 200
0 200
70 100
70 100

Operating Instructions

Model NB0040

6.

Remove nailer

 

 

 

from work sur-

 

 

 

face. The Work

 

 

 

Contact Element

 

 

 

(WCE) must

 

 

 

return to its

 

 

 

original down

 

 

 

position. Pull the trigger. The nailer

 

MUST NOT OPERATE. Do not use the

 

tool if it operates while lifted from

 

the work surface. Personal injury may

 

result.

 

 

7. Pull the trig-

1

2

 

ger and

 

 

 

 

depress the

 

 

 

Work

 

 

 

Contact

 

 

 

Element

 

 

 

(WCE) against the work surface. The

 

nailer MUST OPERATE.

 

8.

Depress the

1

2

 

Work

 

 

 

 

Contact

 

 

 

Element

 

 

 

(WCE)

 

 

 

against

 

 

 

work surface. Pull the trigger. The

 

nailer MUST

 

 

 

OPERATE.

 

 

LOADING/UNLOADING THE NAILER

1.

Always connect

 

 

 

the tool to the

 

 

 

air supply before

 

 

 

loading fasten-

 

 

 

ers.

 

 

2.

Press down on

 

 

 

latch and pull

 

 

 

back on the

 

 

 

magazine

 

 

 

cover.

 

 

3. Insert a stick of

 

 

 

Campbell

 

 

 

Hausfeld nails

 

 

 

or equivalent

 

 

 

(see

 

 

 

"Fasteners" sec-

 

 

 

tion) into the magazine. Make sure

 

the pointed ends of the nails are

 

resting on the bottom ledge of the

 

magazine when loading. Make sure

 

the nails are not dirty or damaged.

4.

Push the

 

 

 

magazine

 

 

 

cover for-

 

 

 

ward until

 

 

 

the latch

 

 

 

catches.

 

 

5.Always unload all fasteners before removing tool from service.

Unloading is the reverse of loading, except always disconnect the air supply before unloading.

ADJUSTING THE NAIL PENETRATION

1.Regulate the air pressure to 70 psi at the nailer.

2.Connect the

air supply and test for penetration by driving

nails into a

sample piece of wood. If the nails do not achieve the desired penetra- tion, adjust the air pressure to a higher setting until the desired pen- etration is achieved. Do not exceed 110 psi at the nailer or durability of the nailer will be reduced.

ADJUSTING THE DIRECTION OF THE EXHAUST

The NB0040 is

 

equipped with an

 

adjustable direc-

 

tion exhaust

 

deflector. This is

Rotate

intended to allow

the user to change the direction of the exhaust. Simply twist the deflector to any direction desired.

CLEARING A JAM FROM THE NAILER

1.Disconnect the air supply from

the nailer.

2. Remove all nails from the magazine (see "Loading/ Unloading The Nailer"). Failure to do

so will cause the nails to eject from the front of the nailer.

3. Undo latch by pulling out

and down. The wire latch will disengage

from the hooks on the nose.

4. The door can now be rotat- ed exposing the jammed fastener.

5. Remove the jammed fas- tener, using pliers or a screwdriver if required.

6. Rotate door back into the closed position.

7. Extend the wire latch and place over the hooks on the nose.

8. Close the latch by pushing the latch up and in until the latch snaps into place.

9.

Make sure the

 

trigger and work

 

contact element

 

(WCE) move

 

freely up and

 

down without

 

sticking or binding.

TECHNICAL SUPPORT

Please call our Nailer hotline at 1-800- 543-6400 with any questions regarding the operation or repair of this nailer. If calling from Ohio or outside of the continental United States, please call, 1-513-367-1182.

Fasteners and Replacement Parts

Use only genuine

Campbell Hausfeld

18 gauge fasteners (or equivalent - See "Fastener Interchange Information"). Use only genuine Campbell Hausfeld replace- ment parts. Never substitute parts. Do not use modified parts or parts which will not provide equivalent performance to the original equipment. Tool perfor- mance, safety, and durability could be reduced. When ordering parts or fasten- ers, specify by part number.

Nailer Repair

Nailer repairs must be performed by a qualified service person or an authorized service center

Assembly Procedure For Seals

When repairing a nailer, the internal parts must be cleaned and lubricated. Parker O-lube or equivalent must be used on all o-rings. Each o-ring must be coat- ed with O-lube before assembling. A small amount of oil must be used on all moving surfaces and pivots. After reassembling, a few drops of 30W non- detergent oil or equivalent, must be added through the air line before testing.

www.campbellhausfeld.com