Model 109SS Temperature Probe

5.1.1.1 Sample Program for CR200 Series Datalogger

'CR200 Series Datalogger

‘This example program measures a single 109SS Thermistor Probe ‘once a second and stores the average temperature every 10 minutes.

‘Declare the variable for the temperature measurement Public Air_Temp

‘Define a data table for 10 minute averages: DataTable (AvgTemp,1,1000)

DataInterval (0,10,min)

Average (1,Air_Temp,0)

EndTable

BeginProg

Scan (1 ,sec)

‘Measure the temperature: Therm109 (Air_Temp,1,1,Ex1,1.0,0) Call the data table:

CallTable AvgTemp

NextScan

EndProg

5.1.1.2 Example 2. Sample Program for CR1000 Datalogger

'CR1000

'Declare Variables and Units

Public T109_C

Units T109_C=Deg C

'Define Data Tables

DataTable(Table1,True,-1)

DataInterval(0,10,Min,10)

Average(1,T109_C,FP2,False)

EndTable

'Main Program

BeginProg

Scan(1,Sec,1,0)

'Default Datalogger Battery Voltage measurement Batt_Volt: '109SS Temperature Probe measurement T109_C: Therm109(T109_C,1,1,1,0,_60Hz,1.0,0.0)

'Call Data Tables and Store Data CallTable(Table1)

NextScan

EndProg

6