TECHNICAL DATA

 

 

 

 

 

 

DIMENSIONS

 

 

 

 

 

 

Height

900 - 915mm

 

 

Width

600mm

 

 

Depth

615mm (excluding door handles)

 

GENERAL

Rp /

 

(

/ ” BSP female)

 

 

Gas connection

 

 

 

 

 

1

2

1

2

 

 

Pressure test point

Grill injector

 

 

Gas rate adjustment

None

 

 

 

 

Aeration adjustment

None

 

 

 

 

Electrical connection

Flexible cord fitted with a 3 pin 13 amp plug

 

 

 

230/240V a.c. 50Hz. 3A fuse.

 

 

 

 

 

BURNER

HEAT INPUT

INJECTOR

 

 

 

 

 

 

 

 

HOTPLATE

3.3 kW

 

 

130

 

Front left

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOTPLATE

3.0 kW

 

 

128

 

Rear Right

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOTPLATE

1.9 kW

 

 

102

 

Front Right & Rear Left

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRILL

3.8 kW

 

 

150

 

MAIN OVEN

2.7 kW

 

 

120

 

 

 

 

 

 

 

TOP OVEN

2.0 kW

 

 

100

 

 

 

 

 

 

 

 

 