ELECTRICAL CONNECTION

WARNING – THIS APPLIANCE MUST BE EARTHED.

CONNECT TO A 230-240V A.C. SUPPLY ONLY.

Connection to the electricity supply should be made via a properly earthed, readily accessible wall socket which is adjacent to but not directly above, and not more than 1.25m away from the appliance and capable of electrical isolation.

The mains lead should be routed such that it cannot touch hot parts of the cooker i.e. the back panel above a height of 650mm from the floor.

Should this plug not fit the socket outlet in your home it should be cut off and replaced with a suitable plug as outlined below.

NOTE: The removed plug cannot be used for any other appliance and should therefore be properly disposed of and not left where children might find it and plug it into a supply socket – with the obvious consequent danger.

IF THE FITTED PLUG IS REMOVED

The flexible mains lead must be correctly connected as below to a three pin plug of not less than 13 amp capacity. If a B.S. 1363 fused plug is used, it must be fitted with a 3 amp fuse which is approved to B.S. 1362.

IMPORTANT: The wires in the mains lead fitted to this appliance are coloured in

accordance with the following code:

GREEN AND YELLOW

– EARTH

 

 

 

 

Blue to

 

BLUE

– NEUTRAL

 

 

 

Neutral

 

BROWN

– LIVE

 

 

 

 

 

 

 

 

 

 

 

Cord Clamp

 

 

 

 

 

Green &

Yellow to

Earth

Brown to Live

3 Amp

Fuse

As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:– The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with

the letter E or by the earth symbol or coloured green or green and yellow. The wire which is coloured blue must be connected to the terminal which is marked with the N or coloured black. The wire which is coloured brown must be connected to the

terminal which is marked with the letter L or coloured red. When wiring the plug, ensure that all strands of wire are securely retained in each terminal. Do not forget to tighten the mains lead clamp on the plug. As the appliance must be earthed, do not use 2-pin

sockets outlets, if you are in doubt, consult a qualified electrician.

Should the mains lead ever require replacement, it is essential that this operation be carried out by a qualified electrician and should only be replaced with a flexible cord of the same size i.e. 0.75mm2 cross sectional area and temperature rating of 850 C e.g. heat resisting PVC.

IF A MOULDED PLUG IS FITTED

In the event of replacing a fuse in the plug supplied a 3 amp ASTA approved fuse to BS1362 must be fitted.

NOTE: The fuse cover must be refitted when changing the fuse. In the event of losing the fuse cover the plug must not be used until a replacement fuse cover has been obtained and fitted. A new fuse cover can be obtained from your local Electricity Board. The colour of the correct replacement fuse cover is that of the coloured marks or inserts in the base of the plug.

Make sure that the cable does not become trapped when pushing the cooker into position.

34

Page 34
Image 34
Cannon ICON 600, 10410G installation instructions Electrical Connection, Connect to a 230-240V A.C. Supply only

10410G, ICON 600 specifications

The Canon ICON 600 (model number 10410G) is a premium multifunction printer that caters to the diverse needs of modern offices and businesses. Renowned for its reliability and efficiency, the ICON 600 is designed to streamline workflows and enhance productivity.

One of the standout features of the Canon ICON 600 is its impressive print speed. Capable of producing up to 60 pages per minute, this printer ensures that large print jobs are completed swiftly, helping to minimize downtime and keep operations running smoothly. The device also boasts a high monthly duty cycle, making it an ideal choice for busy environments with high volume print requirements.

The ICON 600 utilizes advanced imaging technology, ensuring that text and images are printed with exceptional clarity and precision. The maximum print resolution of 1200 x 1200 dpi further enhances image quality, rendering detailed graphics and crisp text outputs that meet the demands of professional documents.

Connectivity is another strong point of the Canon ICON 600. It supports various connectivity options, including USB, Ethernet, and Wi-Fi, allowing easy integration into existing network setups. This multifunction printer also offers mobile printing capabilities through popular cloud services and dedicated mobile apps, giving users the flexibility to print from multiple devices seamlessly.

In addition to its printing prowess, the ICON 600 comes equipped with scanning, copying, and faxing functionalities. The Automatic Document Feeder (ADF) simplifies the handling of multiple documents, allowing users to scan, copy, or fax double-sided pages effortlessly. This multifunctionality means it can serve as a central hub for all document-related tasks in an office.

Furthermore, the Canon ICON 600 is built with security in mind. It features advanced security protocols to safeguard sensitive documents, ensuring that only authorized users have access to various functions. This emphasis on security is essential for businesses that handle confidential information.

The design of the ICON 600 is both compact and stylish, allowing it to fit easily in an office environment without occupying too much space. Its intuitive touchscreen interface simplifies operations, making it accessible for all users, regardless of their technical expertise.

Overall, the Canon ICON 600, 10410G, represents a robust solution for organizations seeking a high-performance, multifunction printer that meets the demands of busy workplaces without compromising on quality or security. With its range of features and capabilities, it is poised to enhance productivity and streamline document management in any setting.