11Replace the Roller Cover.

12Carefully replace the Top Cover.

13Adjust the Adjustment Dial to 5.

For more information, see “Adjusting the Separation Roller Gap” on p. 29.

Adjusting the Separation Roller Gap

If double feed should occur too often, adjust the Separation Roller gap according to the following procedure.

1 Slide the Adjustment Dial Cover to the left.

Adjustment Dial

Turn the dial to the left to widen the gap, and turn it to the right to narrow the gap.

2 Adjust the Adjustment Dial.

Turn the Adjustment Dial to the right 3 clicks.

If documents are not fed after the above operation, turn the Adjustment Dial back to the left 1 click.

3 Slide the Adjustment Dial Cover to the right.

CAUTION

Do not use the Adjustment Dial any other time except when adjusting the Separation Roller gap. Turning the Adjustment Dial too much may damage the scanner.

29