Chapter 2 | Installation |
Power-on Check
When you plug in the
Connecting the Console Terminal
Initial software configuration of the
To connect the
1.Turn on the VT100 terminal (or PC terminal emulator in VT100 or VT52 mode) and set its communication parameters to:
Baud rate: | 9600 bps |
Start bit: | 1 |
Data bits: | 8 |
Stop bit: | 1 |
Parity: | None |
Refer to your terminal’s user manual for instructions on how to set these parameters.
2.Insert the
3.Insert the other end of the cable into the terminal’s
4.Press <Enter> to verify that the cabling process was successful. The system prompt appears (M770sXX:/>).
5.The CLI commands and the explanation of how to configure the switch are described in the Avaya M770 ATM Switch User’s Guide.
8 |