Use the table below to troubleshoot common problems. If you still experience problems, please contact Avaya Communication Technical Support.

Problem

Probable Cause

Solution

 

 

 

BIT LED remains ON

Module self-test failed

i) Check that the module is

after power up or reset

 

correctly and fully inserted into

 

 

the M770 ATM switch chassis

 

 

ii) Reboot or power-up again

All LEDs remain ON

Module fault

Reboot or power-up again

after power up or reset

 

 

Port LED blinks while

Link failure

Check the fiber connection to the

function LED is on

 

port

LNK

 

 

OPR LED does not

The module may be in

Reset the module again but this

light ON after reboot

Monitor mode because

time make a Short Reset (less than 4

(after more than 30

of a Long Reset

seconds)

seconds)

 

 

M15-155 Installation Guide