Table 6 Ð 19XR Heat Exchanger Data

 

 

 

ENGLISH

 

 

 

 

 

SI

 

 

 

 

Dry Rigging Weight

 

Machine Charge

 

Dry Rigging Weight

 

Machine Charge

 

 

(lb)

 

 

 

(kg)

 

CODE

 

 

 

 

 

 

 

 

 

 

 

Cooler

Condenser

Refrigerant

Water Volume

Cooler

Condenser

Refrigerant

 

Water

 

 

 

Weight

 

(gal)

Weight

Volume

 

Only

Only

 

Only

Only

 

Cooler

Condenser

Cooler

Condenser

Cooler

Condenser

Cooler

 

Condenser

 

 

 

 

 

 

10

2,742

2,704

290

200

34

42

1244

1227

132

91

129

 

158

11

2,812

2,772

310

200

37

45

1276

1257

141

91

140

 

170

12

2,883

2,857

330

200

40

49

1308

1296

150

91

152

 

185

15

3,003

2,984

320

250

39

48

1362

1354

145

113

149

 

183

16

3,089

3,068

340

250

43

52

1401

1392

154

113

163

 

198

17

3,176

3,173

370

250

47

57

1441

1439

168

113

178

 

216

20

3,442

3,523

345

225

48

48

1561

1598

156

102

183

 

181

21

3,590

3,690

385

225

55

55

1628

1674

175

102

207

 

210

22

3,746

3,854

435

225

62

63

1699

1748

197

102

234

 

239

30

4,137

3,694

350

260

55

55

1877

1676

159

118

208

 

210

31

4,319

3,899

420

260

64

65

1959

1769

190

118

242

 

246

32

4,511

4,100

490

260

72

74

2046

1860

222

118

271

 

282

35

4,409

4,606

400

310

61

62

2000

2089

181

141

232

 

233

36

4,617

4,840

480

310

70

72

2094

2195

218

141

266

 

273

37

4,835

5,069

550

310

80

83

2193

2299

249

141

301

 

314

40

5,898

6,054

560

280

89

96

2675

2746

254

127

338

 

365

41

6,080

6,259

630

280

97

106

2757

2839

286

127

368

 

400

42

6,244

6,465

690

280

105

114

2832

2933

313

127

396

 

433

45

6,353

6,617

640

330

98

106

2881

3001

290

150

372

 

403

46

6,561

6,851

720

330

108

117

2976

3108

327

150

407

 

442

47

6,748

7,085

790

330

116

127

3060

3214

358

150

438

 

481

50

7,015

7,285

750

400

115

128

3181

3304

340

181

435

 

483

51

7,262

7,490

840

400

126

137

3293

3397

381

181

477

 

518

52

7,417

7,683

900

400

133

136

3364

3484

408

181

502

 

552

55

7,559

7,990

870

490

127

142

3428

3624

395

222

481

 

536

56

7,839

8,214

940

490

139

152

3555

3725

426

222

527

 

575

57

8,016

8,434

980

490

147

162

3635

3825

445

222

557

 

613

60

8,270

8,286

940

420

144

159

3751

3758

426

190

546

 

601

61

8,462

8,483

980

420

153

168

3838

3847

445

190

578

 

636

62

8,617

8,676

1020

420

160

177

3908

3935

463

190

604

 

669

65

8,943

9,204

1020

510

160

176

4056

4174

463

231

605

 

668

66

9,161

9,428

1060

510

169

187

4155

4276

481

231

641

 

707

67

9,338

9,648

1090

510

177

197

4235

4376

494

231

671

 

745

70

12,395

13,139

1220

780

224

209

5622

5960

553

354

848

 

791

71

12,821

13,568

1340

780

243

229

5816

6154

608

354

919

 

867

72

13,153

13,969

1440

780

257

248

5966

6336

653

354

974

 

937

75

13,293

14,211

1365

925

245

234

6030

6446

619

420

927

 

885

76

13,780

14,702

1505

925

266

257

6251

6669

683

420

1009

 

971

77

14,159

15,160

1625

925

283

278

6423

6877

737

420

1072

 

1052

80

16,156

15,746

1500

720

285

264

7328

7142

680

327

1080

 

1000

81

16,530

16,176

1620

720

302

284

7498

7337

735

327

1143

 

1075

82

16,919

16,606

1730

720

319

304

7674

7532

785

327

1208

 

1150

85

17,296

17,001

1690

860

313

295

7845

7712

767

390

1183

 

1118

86

17,723

17,492

1820

860

331

318

8039

7934

826

390

1254

 

1205

87

18,169

17,984

1940

860

351

341

8241

8158

880

390

1329

 

1291

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Rigging weights are for standard tubes of standard wall thickness (Turbo-B3 and Spike®n 2, 0.025-in. [0.635 mm] wall).

NOTES:

1.Cooler includes the control panel (LID), suction elbow, and 1¤2 the distribution piping weight.

2.Condenser includes ¯oat valve and sump, discharge elbow, and 1¤2 the distribution piping weight.

3.For special tubes refer to the 19XR Computer Selection Program.

4.All weights for standard 2 pass NIH (nozzle-in-head) design.

10

Page 10
Image 10
Carrier installation instructions 19XR Heat Exchanger Data

19XR specifications

The Carrier 19XR and 19XRV chillers are sophisticated cooling solutions that represent the forefront of HVAC technology. Designed for large commercial and industrial applications, these chillers provide exceptional performance, energy efficiency, and reliability, making them ideal for a variety of environments ranging from hospitals to manufacturing facilities.

One of the most significant features of the Carrier 19XR and 19XRV chillers is their advanced scroll compressor technology. These units employ a tandem scroll design that enhances efficiency while minimizing operational noise. This makes them ideal for urban environments where noise restrictions may be in place. Moreover, the compressors are equipped with variable speed drive options in the 19XRV model, which allows for greater energy savings by adjusting cooling output based on real-time demand.

In addition to their advanced compressors, the 19XR and 19XRV units incorporate the Carrier GreenChoice refrigerant, which has a lower global warming potential compared to traditional refrigerants. This innovative choice not only meets regulatory requirements but also contributes to sustainability goals, making these chillers a responsible choice for environmentally conscious organizations.

The units are engineered with a robust heat exchanger design, which enhances heat transfer efficiency and overall system performance. This ensures optimal operation even in extreme conditions. They feature a microprocessor-based control system that allows for precise monitoring and control of the chiller’s performance, enabling operators to make real-time adjustments to maximize energy efficiency.

The Carrier 19XR and 19XRV chillers also prioritize serviceability. The design incorporates easy access to key components, simplifying maintenance procedures and reducing downtime. This focus on maintainability extends the lifespan of the equipment, leading to lower lifecycle costs.

In terms of connectivity, these chillers are equipped with advanced Building Management System (BMS) integration capabilities. This allows for seamless monitoring and control of the chillers using a centralized platform, facilitating energy management and operational optimization.

Overall, the Carrier 19XR and 19XRV chillers stand out in the market for their blend of cutting-edge technology, energy efficiency, and user-friendly features. They are engineered to meet the demanding needs of modern commercial and industrial applications, making them a preferred choice for facility managers seeking reliable cooling solutions.