27
HEAT PUMP HEATING PERFORMANCE (CONT.)
INDOOR AIR OUTDOOR COIL ENTERING AIR TEMPERATURES ˚F(˚C)
--- 3 ( --- 1 9 . 4 ) 7 (---13.9) 17 (---8.3) 27 (---2.8) 37 (2.8) 47 (8.3) 57 (13.9) 67 (19.4)
EDB CFM Capacity MBtuh To ta l Sy s -
tem KW†
Capacity MBtuh To t al Sy s -
tem KW†
Capacity MBtuh To t al Sy s -
tem KW†
Capacity MBtuh To ta l Sy s -
tem KW†
Capacity MBtuh To t al Sy s -
tem KW†
Capacity MBtuh To t al Sy s -
tem KW†
Capacity MBtuh To ta l Sy s -
tem KW†
Capacity MBtuh To t al Sy s -
tem KW†
Total Integ* To ta l Integ* To t a l Integ* To t a l Integ* Total Integ* Total Integ* To ta l Integ* To t a l Integ*
25HCR336C30 Outdoor Section With FC4DN(F,B)036 Indoor Section
65
1050 15.00 13.80 2.30 18.51 17.01 2.40 22.45 20.47 2.52 26.85 23.85 2.68 31.67 28.82 2.84 35.35 35.35 2.97 39.39 39.39 3.14 41.38 41.38 3.22
1200 15.19 13.97 2.31 18.73 17.21 2.40 22.70 20.69 2.52 27.13 24.09 2.67 31.46 28.63 2.79 34.88 34.88 2.92 37.68 37.68 3.03 38.03 38.03 3.03
1350 15.37 14.14 2.33 18.92 17.39 2.41 22.91 20.89 2.52 27.37 24.31 2.67 31.15 28.35 2.77 34.37 34.37 2.88 35.27 35.27 2.91 35.72 35.72 2.92
70
1050 14.67 13.50 2.39 18.22 16.74 2.51 22.12 20.17 2.63 26.49 23.52 2.80 31.32 28.50 2.99 35.45 35.45 3.12 39.57 39.57 3.30 42.44 42.44 3.43
1200 14.86 13.67 2.41 18.42 16.93 2.51 22.37 20.39 2.63 26.76 23.77 2.78 31.52 28.68 2.93 35.00 35.00 3.06 38.80 38.80 3.22 39.67 39.67 3.25
1350 15.04 13.84 2.42 18.60 17.09 2.52 22.57 20.58 2.63 26.99 23.97 2.78 31.29 28.47 2.90 34.58 34.58 3.03 36.93 36.93 3.12 37.20 37.20 3.12
75
1050 14.32 13.17 2.49 17.88 16.43 2.62 21.77 19.85 2.75 26.10 23.18 2.92 30.91 28.13 3.13 35.47 35.47 3.28 39.61 39.61 3.47 43.96 43.96 3.68
1200 14.52 13.36 2.50 18.09 16.63 2.62 22.01 20.07 2.74 26.40 23.45 2.90 31.25 28.44 3.08 35.14 35.14 3.21 38.99 38.99 3.38 41.08 41.08 3.47
1350 14.70 13.52 2.52 18.28 16.80 2.63 22.23 20.27 2.74 26.63 23.65 2.90 31.36 28.54 3.05 34.75 34.75 3.17 38.21 38.21 3.32 38.89 38.89 3.33
Heating Indoor Model Capacity Power Furnace Model
*FC4DN(F,B)036 1.00 1.00
FC4DN(F,B)042 0.92 0.93
FK4DNF002 1.04 1.01
FK4DNF003 1.00 0.99
CAR**3614A** 0.98 1.00 58CV(A,X)070---12
CNRH*3617A** 1.02 1.03 58CV(A,X)070---12
CNRH*4221A** 1.00 0.99 58CV(A,X)070---12
CSRH*3612A** 0.98 0.98 58CV(A,X)070---12
CSRH*4212A** 0.97 0.96 58CV(A,X)070---12
CAR**3617A** 1.01 1.01 58CV(A,X)090---16
CNRH*3617A** 1.01 1.01 58CV(A,X)090---16
CNRH*4221A** 0.99 0.97 58CV(A,X)090---16
CNRV*3617A** 1.01 1.01 58CV(A,X)090---16
CSRH*3612A** 0.98 0.97 58CV(A,X)090---16
CSRH*4212A** 0.97 0.95 58CV(A,X)090---16
CAR**3621A** 1.01 1.00 58CV(A,X)110---20
CAR**4221A** 0.99 0.98 58CV(A,X)110---20
CNRH*3617A** 1.01 1.01 58CV(A,X)110---20
CNRH*4221A** 0.99 0.97 58CV(A,X)110---20
CNRV*3621A** 1.01 1.01 58CV(A,X)110---20
CNRV*4221A** 0.99 0.97 58CV(A,X)110---20
CSRH*3612A** 0.98 0.96 58CV(A,X)110---20
CSRH*4212A** 0.96 0.94 58CV(A,X)110---20
CAR**4224A** 0.99 0.98 58CV(A,X)135---22
CNRH*3617A** 1.01 1.01 58CV(A,X)135---22
CNRH*4221A** 0.99 0.96 58CV(A,X)135---22
CSRH*3612A** 0.98 0.96 58CV(A,X)135---22
CSRH*4212A** 0.96 0.94 58CV(A,X)135---22
CAR**4224A** 0.99 0.97 58CV(A,X)155---22
CNRH*3617A** 1.01 1.01 58CV(A,X)155---22
CNRH*4221A** 0.99 0.96 58CV(A,X)155---22
CSRH*3612A** 0.98 0.95 58CV(A,X)155---22
CSRH*4212A** 0.96 0.93 58CV(A,X)155---22
CAR**4224A** 1.00 1.00 58MVB040---14
CNRH*3617A** 1.01 1.03 58MVB040---14
CNRH*4221A** 1.00 0.99 58MVB040---14
CSRH*3612A** 0.99 0.98 58MVB040 ---14
CSRH*4212A** 0.97 0.97 58MVB040 ---14
CAR**3617A** 1.01 1.01 58MVB060---14
CNRH*3617A** 1.01 1.02 58MVB060---14
CNRH*4221A** 0.99 0.98 58MVB060---14
Heating Indoor Model Capacity Power Furnace Model
CNRV*3617A** 1.01 1.02 58MVB060---14
CSRH*3612A** 0.98 0.97 58MVB060 ---14
CSRH*4212A** 0.97 0.95 58MVB060 ---14
CAR**3621A** 1.01 1.02 58MVB080---14
CAR**4221A** 1.00 1.00 58MVB080---14
CNRH*4221A** 1.00 0.99 58MVB080---14
CNRV*4221A** 1.00 0.99 58MVB080---14
CSRH*3612A** 0.99 0.99 58MVB080 ---14
CSRH*4212A** 0.97 0.97 58MVB080 ---14
CAR**3621A** 1.01 1.01 58MVB080---20
CAR**4221A** 1.00 1.00 58MVB080---20
CNRH*3617A** 1.01 1.02 58MVB080---20
CNRH*4221A** 0.99 0.98 58MVB080---20
CNRV*3621A** 1.01 1.02 58MVB080---20
CNRV*4221A** 0.99 0.98 58MVB080---20
CSRH*3612A** 0.98 0.97 58MVB080 ---20
CSRH*4212A** 0.97 0.95 58MVB080 ---20
CAR**3621A** 1.01 1.01 58MVB100---20
CAR**4221A** 1.00 0.99 58MVB100---20
CNRH*3617A** 1.01 1.02 58MVB100---20
CNRH*4221A** 0.99 0.98 58MVB100---20
CNRV*3621A** 1.01 1.02 58MVB100---20
CNRV*4221A** 0.99 0.98 58MVB100---20
CSRH*3612A** 0.98 0.97 58MVB100 ---20
CSRH*4212A** 0.97 0.95 58MVB100 ---20
CAR**4224A** 0.99 0.98 58MVB120---20
CNRH*3617A** 1.01 1.02 58MVB120---20
CNRH*4221A** 0.99 0.97 58MVB120---20
CSRH*3612A** 0.98 0.97 58MVB120 ---20
CSRH*4212A** 0.97 0.95 58MVB120 ---20
CAR**3617A** 1.01 1.01 58UVB060---14
CNRV*3617A** 1.01 1.02 58UVB060---14
CAR**3621A** 1.01 1.02 58UVB080---14
CAR**4221A** 1.00 1.00 58UVB080---14
CNRV*4221A** 1.00 0.99 58UVB080---14
CAR**3621A** 1.01 1.01 58UVB080---20
CAR**4221A** 1.00 1.00 58UVB080---20
CNRV*3621A** 1.01 1.02 58UVB080---20
CNRV*4221A** 0.99 0.98 58UVB080---20
CAR**3621A** 1.01 1.01 58UVB100---20
CAR**4221A** 1.00 0.99 58UVB100---20
Heating Indoor Model Capacity Power Furnace Model
CNRV*3621A** 1.01 1.02 58UVB100---20
CNRV*4221A** 0.99 0.98 58UVB100---20
CAR**4224A** 0.99 0.98 58UVB120---20
See notes on page 30