1
Models 336, 338 & 339 To the Installer
031030
Section 1 To the InstallerThesemachines are designed forindoor use only.
DONOT install the machines in an area where
a water jet could be used. Failure to follow this
instruction may result in serious electrical shock .
Water Connections
(Water Cooled Units Only)
An adequate cold water supply must be provided wit h
a hand shut-off valve. On the underside rear of the
base pan, two 1/2” I.P.S. water connections for inlet
and outlet have been provided for easy hook-up. 1/2”
insidediam eter water lines should be connected to the
machine. (Flexible lines are recommended, if local
codes permit.) Depending on local water conditions, it
may be advisable to install a water strainer to prevent
foreign substances from clogging the automatic water
valve. There will be only one water “in” and one water
“out” connection for both single-head and double- head
units. DO NOT install a hand shut-off valve on the
water “out” line! Water should always flow in this order:
first, through the automatic water valve; second,
through the condenser; and third, through t he outlet
fitting to an opentrapdrain.
Air Cooled Units
Air cooled units require a minimum of 3” (76 mm) of
clearance around all sides of the freezer to allow for
adequate air flow across the condenser(s). Failure to
allow adequate clearance can reduce the refrigeration
capacity of the freezer and possibly cause permanent
damage to the compressor.
Electrical Connections
Each freezer requires one power supply for each data
label. Check the data label(s) on the freezer for f use,
circuit ampacity and electrical specifications. Refer to
thewiring diagr am provided inside of the electrical box,
for proper power connections.
In the United States, this equipment isintended tobe
installed in accordance with the National Electrical
Code (NEC), ANSI/NFPA 70--1987. The purpose of
the NEC code is the practical safeguarding of persons
and property from hazards arising from the use of
electricity. This code contains provisions considered
necessary for safety. Compliance therewith and
proper maintenance will result in an installation
essentially free from hazard!
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
Stationary appliances which are not equipped with a
power cord and a plug or other device to disconnect
the appliance from the power sourc e must have an
all--poledisconnect ing device with a contact gap of at
least 3 mm installed in the external installation.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
Beater rotation must be clockwise as viewed looking
into the freezing cylinder of any model freezer.
Note: The following procedures should be performed
by a trained service technician.
Tocorrect rotation on a three-phase unit, interchange
any two incoming power supply lines at freezer main
terminal block only.
Tocorrect rotation on a single-phase unit, change the
leads inside the beater motor. (Follow diagram printed
on motor.)
Electrical connections are made directly to the
terminal block provided in the main control box located
behind the service panel.